Getting Started; Functions Menu - CAME BXV06AGL Installation Manual

Table of Contents

Advertisement

PROGRAMMING
Programming button functions

Getting started

Once the electrical connections have been made, proceed with commissioning. Only skilled and qualified staff may perform this operation.
Make sure that there are no obstacles in the way.
Power up the device and begin programming.
Start programming with the F54 function (opening direction).
After powering up the system, the first manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system.
If the three display segments are flashing, calibrate the travel.

Functions menu

Total stop
Stop the gate and exclude automatic closing. Use a control device to resume movement.
F1
CX input
Associate a function with the CX input.
F2
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
Stop the operator
2
< > buttons
The < > buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
Open or close the operator
ENTER button
3
The ENTER button is used to perform the operations described below.
Access menus
Confirm choice
OFF (Default)
ON
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop
Only with [F19 - Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopening during closure (sensitive edges)
C8 = Reclose while opening (sensitive edges)

Advertisement

Table of Contents
loading

Table of Contents