Advertisement

Quick Links

SIXPAR 100IP &
SIXPAR 100WMG
user manual

Advertisement

Table of Contents
loading

Summary of Contents for Elation SIXPAR 100WMG

  • Page 1 SIXPAR 100IP & SIXPAR 100WMG user manual...
  • Page 2 Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 (728) 282-7070...
  • Page 3: Table Of Contents

    C O N T E N T S General Information Warranty Returns (USA Only) IP65 Rated Safety Guidelines Overview Torque Settings for Screws IP Test Parameters Installation Guidelines Remote Device Management (RDM) DMX Setup System Menu Dimmer Mode DMX Channel Functions and Values Primary-Secondary Set Up Maintenance Guidelines Specifications...
  • Page 4: General Information

    Female 5pin XLR to IP Male DMX Output Cable 3.3 ft (1m) Manual & Warranty Card CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments or suggestions. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com...
  • Page 5: Warranty Returns (Usa Only)

    B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States.
  • Page 6: Ip65 Rated

    I P 6 5 R AT E D The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
  • Page 7: Safety Guidelines

    This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
  • Page 8 S A F E T Y G U I D E L I N E S RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV LED. WEAR PROPER EYE AND SKIN PROTECTION.
  • Page 9: Overview

    O V E R V I E W System Menu LCD & Controls Mounting Brackets/Yokes Valve Power Out “S” Knobs to tighten DMX OUT Brackets/Yokes Lens POWER IN DMX IN...
  • Page 10: Torque Settings For Screws

    T O R Q U E S E T T I N G S F O R S C R E W S The hex-head screws holding either the panels or the base MUST be tightened with a torque wrench (not included). TORQUE SETTING = 11 lbf-in.
  • Page 11: Ip Test Parameters

    Following any repair or maintenance procedure that requires disassembly of the fixture, use Elation’s IP Tester to confirm the IP integrity of the fixture. The air valve is located on the back panel next to the display screen, as shown in the diagram below. Please contact Elation...
  • Page 12: Installation Guidelines

    I N S TA L L AT I O N G U I D E L I N E S FLAMMABLE MATERIAL WARNING Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE.
  • Page 13 I N S TA L L AT I O N G U I D E L I N E S MOUNTING THE FIXTURE ON A TRUSS USING CLAMP When mounting the fixture to a truss, be sure to secure an appropriately rated professional grade rigging clamp (not included) to the closed dual yokes using an M10 screw fitted through the center hole of the closed dual yokes.
  • Page 14 I N S TA L L AT I O N G U I D E L I N E S RIGGING Overhead rigging requires extensive experience, including among others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture.
  • Page 15: Remote Device Management (Rdm)

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used through- out the entire system, including DMX data splitters and wireless systems.
  • Page 16: Dmx Setup

    D M X S E T U P DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller.
  • Page 17 D M X S E T U P DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen”...
  • Page 18: System Menu

    SYSTEM MENU ON-BOARD SYSTEM MENU The SIXPAR 100IP™ comes with an easy to navigate system menu. The next sections will cover how to access each menu function. LCD CONTROL PANEL DISPLAY The (4) button control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SIXPAR 100IP™.
  • Page 19 S YS T E M M E N U ELATION SIXPAR 100IP Supports Software Versions: ≥ 1.3 OPTIONS / VALUES MAIN MENU DESCRIPTION (Default Settings in BOLD) Channel CH: 06, 07, 08, 12 DMX Channel Mode DMX Mode ADDR: 001 ~ 512...
  • Page 20: Dimmer Mode

    D I M M E R M O D E...
  • Page 21: Dmx Channel Functions And Values

    D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S ELATION SIXPAR 100IP DMX Channel Values / Functions Supports Software Versions: ≥...
  • Page 22 ELATION SIXPAR 100IP DMX Channel Values / Functions Supports Software Versions: ≥ 1.0 Features subject to change without notice MODE/CHANNEL VALUE FUNCTION 12CH 116-119 RED + WHITE + AMBER 120-123 RED + WHITE + UV 124-127 RED + AMBER + UV...
  • Page 23: Primary-Secondary Set Up

    P R I M A R Y- S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs.
  • Page 24: Maintenance Guidelines

    Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
  • Page 25: Specifications

    S P E C I F I C AT I O N S SOURCE (7) 12W 6-in-1 RGBAW+UV LEDs 100,000 Hour Average LED Life* *LED Life may vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
  • Page 26 P H O T O M E T R I C D ATA D I M E N S I O N S *Drawings not to scale. Specifications and improvements in the design of this unit and this manual are subject to change without notice.
  • Page 27: Optional Accessories | Fcc Statement

    O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM SIXPAR100/GFH Gel Frame Holder Kit SIXPAR/BD100 Barn Door NOTE: Gel Frame Holder Kit required to attach Barn Door. (Sold separately) SIXPAR/2MDLC 6.6 ft.

This manual is also suitable for:

Sixpar 100ip

Table of Contents