G A S L E A K T E S T I N G
Use a brush and liquid detergent to test all gas
connections for leaks. Bubbles around connec-
tions will indicate a leak. If a leak appears, shut
off gas valve controls and adjust connections.
Then check connections again. Clean all the
detergent solution from the cooktop.
Never test for a gas leak with a match or
other flame.
C O M P L E T I N G T H E I N S TA L L AT I O N
Once the cooktop has been checked for any
gas leaks, plug the power supply cord into the
grounded electrical outlet.
Place the burner head on the burner base and
position the burner grate over the burner
assembly.
IMPORTANT NOTE: Do not seal the cooktop
to the countertop. It must be removed if
service is necessary.
Shut-Off
Valve
1
/
" Adapter
2
Flexible Metal
1
/
" Nipple
Connector
2
(use pipe-joint
compound on ends)
Gas supply line connection
Dimensions in parentheses are in
millimeters unless otherwise specified.
S U R FAC E
I N I T I A L L I G H T I N G
The cooktop burner uses an electronic igniter
in place of a standing pilot. When the cooktop
control knob is pushed in and turned to the
HIGH position, the system creates a spark to
light the burner. This sparking continues until
the electronic ignition senses a flame.
To check operation of the cooktop burner, push
in and turn the control knob to the HIGH
position. The flame should light within four
seconds.
If the burner does not light properly, turn the
control knob to the OFF position. Check that
the burner head is in the proper position.
Check that the power supply cord is plugged in
and that the circuit breaker or house fuse has
not blown. Make sure that the shut-off valve is
in the ON position. Check operation again; if
the burner does not light properly at this point,
contact a Wolf authorized service center.
IMPORTANT NOTE: Initial lighting of the
cooktop burner may take slightly longer as air
in the system must be purged before gas can
be supplied to the burner.
Pressure
Regulator
1
/
" Adapter
2
1
/
" Nipple
2
(use pipe-joint
compound on ends)