Kenwood TK-701S Service Manual page 34

Synthesized fm two-way radio
Table of Contents

Advertisement

[K-701S
12. Test equipment required
Test Equipment
Major Specifications
. Standard Signal Generator
(SSG)
Frequency range
Modulation
Output
150 ~ 174 MHz
Frequency modulation and external modulation.
0.1 uV to greater than 1 mV.
. Power meter
Input impedance
Operation frequency
Measurement capability
50 ohms
150 to
174 MHz or more.
Vicinity of 1OOW and 10W.
3. Deviation meter
Frequency range
150 ~ 174 MHz
4. Digital volt meter (DVM)
Measuring range
1 ~ 10V DC.
Accuracy
High input impedance for minimum circuit loading.
5. Oscilloscope
DC through 30 MHz.
6. High sensitivity frequency
Frequency range
10 MHz to 200 MHz.
counter
Frequency stability
0.2 ppm or less.
7. Ammeter
15A
8. AF volt meter
Frequency range
50 Hz to 10 kHz.
Voltage range
3 mV to 30V.
9. Audio generator
Frequency range
50 Hz to 5 kHz or more.
Output
Fine adjustment capable between O and 1V.
10. Distortion meter
Capability
3% or less at 1 kHz.
Input level
50 mV to 10V rms.
11. VOM
Measuring range
Measurable between 1.5 ~ 10V DC or less.
Input impedance
50kohms/V or greater.
12. 40hm dummy load
Approx. 4 ohm, 10W.
13.
Regulated power source
13.8V, approx. 15A (adjustable from 9 to
17V)
Useful if ammeter equipped.
14.
Spectrum analyzer
Frequency range
0 ~ 1200 MHz (2nd and 3rd harmonic frequencies
measurable}
Frequency within fo + 100 kHz mesurabie.
5-6