Gun air shutoff kit
Table of Contents

Advertisement

Installation
Install Atomizing Air Shutoff Valve
1. Mount the shutoff valve (2) securely. (See F
page 4.)
2. Install bushing (6) and muffler (9) in the upper port
(N/O-Normally Open). (See F
3. Connect atomizing air line from AFS (A) to lower
port (B;N/C-Normally Closed).
4. Connect an air line from solenoid fitting (4) to
pilot port (D).
5. Connect an air line from the outlet port (C) to the
gun air inlet.
A
C
F
. 10: Air Line Connections, ProMix II
IG
12
IG
. 10 for steps 2-5.)
IG
4
D
2
6,9 (N/O)
B (N/C)
. 1 on