Download Print this page

LG Therma V FHNW16606C0 Data Book page 37

Advertisement

THERMA V
Monobloc
7. Capacity Tables
 FHBW146B0 [HM141HF UB60], FHBW148B0 [HM143F UB60]
Outdoor
Temperature
LWT 7 °C
[°C DB]
TC
EER
20
12.00
3.97
30
12.00
3.32
35
12.00
2.99
40
10.68
2.64
45
9.36
2.27
Note
1. DB : Dry bulb temperature(℃), LWT : Leaving water temperature(℃), LPM : Liter per minute ( ℓ /min)
2. TC : Total capacity(kW), EER: Energy efficiency ratio(kW/kW), COP : Coefficient of performance (kW/kW)
3. Direct interpolation is permissible. Do not extrapolate.
4. Measuring procedure follows EN14511.
• Rated values are based on standard conditions, and it can be found on specifications.
• Above table values may not be matched according to installation condition. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard(or nations), the results may vary.
5. The Shaded areas are not guaranteed continuous operation.
Water flow rate 34.5 LPM
LWT 10 °C
LWT 13 °C
TC
EER
TC
EER
12.00
4.30
12.00
4.63
12.00
3.71
12.00
4.01
12.00
3.22
12.00
3.45
11.52
2.81
12.00
2.98
10.17
2.41
10.98
2.52
LWT 15 °C
LWT 18 °C
TC
EER
TC
EER
12.00
4.85
12.00
5.20
12.00
4.26
12.00
4.49
12.00
3.67
12.00
3.70
12.00
3.14
12.00
3.29
11.51
2.60
12.00
2.73
Product Data
LWT 20 °C
LWT 22 °C
TC
EER
TC
EER
12.00
5.43
12.00
5.66
12.00
4.62
12.00
4.58
12.00
3.97
12.00
4.03
12.00
3.40
12.00
3.49
12.00
2.84
12.00
2.95
23