Download Print this page

LG Therma V FHNW16606C0 Data Book page 35

Advertisement

THERMA V
Monobloc
7. Capacity Tables
7.2 Cooling Operation
■ Maximum Capacity
 FHBW098X0 [HM093HFX UB60]
Outdoor
Temperature
LWT 7 °C
[°C DB]
TC
EER
20
9.00
4.30
30
9.00
3.59
35
9.00
3.24
40
8.01
2.84
45
7.02
2.41
Note
1. DB : Dry bulb temperature(℃), LWT : Leaving water temperature(℃), LPM : Liter per minute ( ℓ /min)
2. TC : Total capacity(kW), EER: Energy efficiency ratio(kW/kW), COP : Coefficient of performance (kW/kW)
3. Direct interpolation is permissible. Do not extrapolate.
4. Measuring procedure follows EN14511.
• Rated values are based on standard conditions, and it can be found on specifications.
• Above table values may not be matched according to installation condition. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard(or nations), the results may vary.
5. The Shaded areas are not guaranteed continuous operation.
Water flow rate 25.9 LPM
LWT 10 °C
LWT 13 °C
TC
EER
TC
EER
9.00
4.65
9.00
5.01
9.00
4.00
9.00
4.30
9.00
3.44
9.00
3.65
8.64
3.01
9.00
3.17
7.63
2.57
8.23
2.71
LWT 15 °C
LWT 18 °C
TC
EER
TC
EER
9.00
5.26
9.00
5.63
9.00
4.55
9.00
4.80
9.00
3.85
9.00
3.90
9.00
3.32
9.00
3.49
8.63
2.80
9.00
2.95
Product Data
LWT 20 °C
LWT 22 °C
TC
EER
TC
EER
9.00
5.88
9.00
6.14
9.00
4.96
9.00
4.96
9.00
4.21
9.00
4.37
9.00
3.64
9.00
3.78
9.00
3.07
9.00
3.19