4.13 Servomotor SQM41 ...

Warnings
To avoid accidents, material or environmen-
tal damage, observe the following instruc-
tions!
WARNING
Avoid opening, modifying or forcing the ser-
vomotor.
 All interventions (assembly and installation operations,
assistance, etc.) must be carried out by qualified personnel.
 Falls and collisions can negatively affect the safety func-
tions. In this case, the servomotor must not be operated,
even if it displays no evident damage.
 Fully disconnect the burner from the mains when working
near terminals and servomotor connections.
 Condensation and exposure to water are not allowed.
 For safety reasons, the servomotor must be checked after
long periods of non-use.

4.14 Calibration of the thermal relay

The thermal relay serves to avoid damage to the motor due to an
excessive absorption increase or if a phase is missing.
For calibration 2), see the table in the wiring diagram.
To reset, in case of an intervention of the thermal relay, press the
"RESET" button 1) of Fig. 8.
The red "TEST" button 3) opens the NC (95-96) contact and
stops the motor.
The automatic reset can be dangerous. This oper-
ation is not foreseen in the burner operation.
Therefore do not position the "RESET" button
1) on "A".
CAUTION
20160598
Technical description of the burner
Technical data
14
GB
S8907
Mains voltage
230 V -15% +10%
Mains frequency
50 / 60 Hz
Power absorption
7 ... 15 VA
Motor
Synchronous
Drive angle
Varying between 0° and 135°
Absolutely do not adjust the red cam No. 1 more
than 90° to prevent serious or irreversible damage
to the mechanical adjustment parts.
WARNING
Protection level
Max. IP 66, with appropriate cable
entry
Cable entry
2 x M16
Cable connection
terminal board for 0.5mm
and 2.5mm
Rotation direction
Clockwise
Rated torque (max.)
10 Nm
Holding torque
5 Nm
Operation time
30 s. at 90°
Weight
approx. 2 kg
Environmental conditions:
Operation
-20....+60° C
Transport and storage
-20...+60°C
2
20073932
Fig. 7
2
(min.)
2
(max.)
Tab. F