Sony CCD-F35 Service Manual page 162

Video camera recorder
Table of Contents

Advertisement

7-2-22.
Indoor White Balance Adjustment
(Method using vectorscope)
Color bar chart standard picture frame
Subject
7-2-23.
Indoor White Balance Adjustment
(Method using oscilloscope) (CV-8 Board)
Subject
Color bar chart standard picture frame
2)
Change the adjustment data with the adjustment remote
commander to move the white luminance point to the otigin
point.
3)
Set the adjustment address to 12.
4) Change the adjustment data to move the white luminance
point to the origin point. . . .
mg
5) Repeat steps 1) through 4)."
6)
Change the adjustment address to store the adjustment data
in the memory.
R-Y
B-
White luminance ~ 7
een
point
Move the white
luminance point
to the origin point
Fig. 7-28.
2) Change the adjustment data with the adjustment remote
commander to move the white luminance point with the
black luminance point.
3)
Set the adjustment address to 12.
4) Change the adjustment data to move the white luminance
point to the black luminance point.
5) Repeat
steps 1) through 4).
6) Change the adjustment address to store the adjustment data
in the memory.
bed
Ry Magenta
\
Move the white luminance
point to the black
Yellow
A
.
luminance point
ane
B-Y
o> Bue
4
t
Fig. 7-29,
~@
Green
cyan
— 216 —