Duct Connected-High Static Pressure Type (Fdu) - Mitsubishi Heavy Industries FDT125VNPWVH Data Book

Standard inverter packaged air-conditioners, split system, air to air heat pump type, ceilining cassette-4 way type, duct connected-high static pressure type, duct connected-low/middle static pressure type, ceiling suspended type
Table of Contents

Advertisement

(2) Duct connected-High static pressure type (FDU)

Item
Power source
Nominal cooling capacity (range)
Nominal heating capacity (range)
Power consumption
Max power consumption
Running current
Inrush current, max current
Operation data
Power factor
EER
COP
Sound power level
Sound pressure level
Silent mode
sound pressure level
Exterior dimensions (Height x Width x Depth)
Exterior appearance
(Munsell color)
(RAL color )
Net weight
Compressor type & Q'ty
Compressor motor (Starting method)
Refrigerant oil (Amount, type)
Refrigerant (Type, amount, pre-charge length)
Heat exchanger
Refrigerant control
Fan type & Q'ty
Fan motor (Starting method)
Air flow
Available external static pressure
Outside air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Electric heater
Remote control
Operation
Room temperature control
control
Operation display
Safety equipments
Refrigerant piping size (O.D)
Connecting method
Attached length of piping
Installation data
Insulation for piping
Refrigerant line (one way) length
Vertical height diff. between O /U and I/U
Drain hose
Drain pump, max lift height
Recommended breaker size
L.R.A. (Locked rotor ampere)
Interconnecting wires
IP number
Standard accessories
Option parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) This air-conditioner is manufactured and tested in conformity with the ISO and AS/NZS.
(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.
(6) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.
(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",
E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)
Model
kW
kW
Cooling
Heating
kW
Cooling
Heating
A
Cooling
%
Heating
Cooling
Heating
Cooling
Heating
Cooling
dB(A)
Heating
Cooling
Heating
mm
kg
kW
L
kg
W
Cooling
m
3
/min
Heating
Pa
W
Liquid line
mm
Gas line
m
m
m
mm
A
A
Size x Core number
Indoor air temperature
Outdoor air temperature
DB
WB
DB
27˚C
19˚C
35˚C
20˚C
7˚C
Indoor unit
FDU125VH
1 Phase 220-240V 50Hz / 220V 60Hz
12.1 [5.0 (Min.) — 12.1 (Max.)]
12.1 [4.0 (Min.) — 13.3 (Max.)]
67
P-Hi: 45 Hi: 40 Me: 34 Lo: 29
280 × 1370 × 740
54
R32 2.25 in outdoor unit (Incl. the amount for the piping of 15m)
Louver fin & inner grooved tubing
Electronic expansion valve
Centrifugal fan × 3
100 + 200 <Direct line start>
P-Hi: 39 Hi: 32 Me: 26 Lo: 20
Standard: 60 Max: 200
Possible
Procure locally
Rubber sleeve (for fan motor)
(Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-KIT4-E2
Thermostat by electronics
Compressor overheat protection, Overcurrent protection
Frost protection, Serial signal error protection, Indoor fan motor error protection
Heating overload protection (High pressure control), Cooling overload protection
I/U φ 9.52 (3/8") Pipe φ 9.52 (3/8") × 0.8 O/U φ 9.52 (3/8")
φ 15.88 (5/8") Pipe φ 15.88(5/8") × 1.0 φ 15.88 (5/8")
Flare piping
Necessary (both Liquid & Gas lines)
Max.20 (Outdoor unit is higher) Max.20 (Outdoor unit is lower)
Hose connectable VP25 (I.D.25, O.D.32)
Built-in drain pump , 600
2
1.5mm
× 4 cores (Including earth cable) / Terminal block (Screw fixing type)
IPX0
Mounting kit, Drain hose
Motion sensor : LB-KIT2
External static pressure
of indoor unit
WB
24˚C
60Pa
6˚C
- 4 -
'22 • PAC-DB-409
FDU125VNPWVH
Outdoor unit
FDC125VNP-W
3.85
3.28
4.75
16.2 / 16.9
13.8 / 14.4
5 , 20
99
99
3.14
3.69
73
72
57
57
45
45
845 × 970 × 370
Stucco white
(4.2Y7.5/1.1) near equivalent
(RAL 7044) near equivalent
73
RMT5126SWP3 (Twin rotary type) × 1
Direct line start
0.9 (M-MB75)
M shape fin & inner grooved tubing
Propeller fan × 1
86 <Direct line start>
75
79
0
Rubber sleeve (for fan motor & compressor)
Flare piping
Max.30
Hole size φ 20 × 3 pcs.
5
IPX4
Drain elbow, Drain hole grommet
The pipe length is 7.5m.
Standards
ISO5151-T1, AS/NZS 3823.2
ISO5151-H1, AS/NZS 3823.2
PJG000Z625
Y
#