Installation - Broan QL100 Series Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

PREPARATION
1.
Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay
out the range hood's mounting holes, wiring access and duc-
twork by marking the cabinet bottom and drywall where appli-
cable. NOTE: Cabinets with recessed bottoms will require wood
shims to make mounting surface flush with cabinet frame.
2.
Make cutouts for wiring and ductwork.
3.
If the hood is to be ducted, install the ductwork so that is flush
to the range hood's mounting surface.
Refer to FIGURE 1 if the range hood is to be installed with a
horizontal discharge.
Refer to FIGURE 2 and FIGURE 3 if the range hood is to be
installed with a vertical discharge.
4.
Run two-conductor wire (with ground) frorn a power source to
the hood location. Bring approximately
12" of wiring through
wiring hole in cabinet.
5.
Drill four 3/32" diameter pilot holes at points where mounting
holes are marked in cabinet bottom.
6.
Insert four (4) mounting screws, leaving approximately 1%" of
thread exposed.
7.
Remove
and retain the mounting screws securing the 3%" x
10" and 7" duct transitions to the hood. Install the appropriate
duct transition as described in the installation section.
INSTALLATION
1.
Remove the necessary duct opening and wiring knockout from
the range hood.
lf the range hood
is to be installed as a non-ducted
unit,
remove the wiring Knockout only.
lf the range hood is to be installed as a ducted unit, a baffle
plate is provided to close off the non-ducted vent. Install baffle
plate (Refer to FIGURE
4) by sliding into place behind grille.
Use locator burps to orient in grille.
2.
For 7" round discharge installation, refer to FIGURE 5. Se-
cure 7" adapter (included) to top of hood using screws provided.
Install 7" round damper (Model BP87 (97010792), purchased
separately).
For 3%" x 10" vertical discharge installation, refer to FIG-
URE 6. Secure 3%" x 10" transition (if used) to top of hood.
For 3%"
x 10"
horizontal
discharge
installation,
refer to
FIGURE 7. If using supplied 314" x 10"
duct transition, secure
it to the range
hood.
Ensure
that the damper flap operates
fully and freely. If it does not, remove the damper flap or make
necessary modifications to the installation to insure full and free
operation of the damper flap.
3.
Feed the wiring through the access hold and into the electrical
box.
4.
Align hood's keyhole mounting slots over the four (4) partially
installed screws.
5.
Making sure the duct positions over the hood's duct transition,
push the hood against the rear wall. Secure hood by tightening
screws.
6.
Using a long blade screwdriver, reach into the discharge open-
ing and make
sure the damper flap operates freely (vertical
discharge only).
LOCATORS
FIGURE 4
7" ROUND
——— ADAPTER
(INCLUDED)
FIGURE 5
SECURE TRANSITION
WITH SCREWS
(INCLUDED)
FIGURE 6
POSITION DUCT
TRANSITION IN
WALL CUTOUT
HORIZONTAL
FIGURE 7

Advertisement

Table of Contents
loading

Table of Contents