Measure Installation; Prepare The Installation - Broan E60000 Series Installation Instructions Manual

Hide thumbs Also See for E60000 Series:
Table of Contents

Advertisement

Available languages

Available languages

2. MEASURE INSTALLATION
Dimensions for the most common installation are illustrated at right.
Ceiling
a
.
Cabinet, soffit,
The minimum
hood distance above cooktop must not be less | yocorative flue or —
than
24'.
A
maximum
of
30"
above
cooktop
is
highly |
non-duct kit flue
recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
iN
mounting strip
I
Top of wood
|
fae
Minimum distance between
the hood and cooktop:
24"
Recommended
maximum
distance between the hood
and cooktop: 30"
| __
Standard 36"
high cooktop
MINIMUM AND MAXIMUM
DISTANCE
OVER COOKTOP
HHO093A
3. PREPARE THE INSTALLATION
Z\ WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Wood strip (attached to back of hood)
- Installation manual
- Accessories including:
«
Baffle filters: 30" and 36" hoods come with 3 baffle filters; 42" and 48" hoods come with 4 baffle filters
«
Baffle filters handles (taped inside the hood)
* 3%" x 10" adapter/damper (included with internal single blower hood)
* « 4%" x 18%" adapter (included with internal double blower hood)
«
|n-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
«
Bag of parts including:
4 flat head screws no. 10-2", 8 screws no. 8 x 3/4", 2 wire connectors, 3 wall anchors,
3 washers 13/64" ID x 3/4" OD, 1 wire clamp, 8 mechanical screws no. 8-32 x 1/4", 4 no. 8 x 3/8" screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331H, 332H, 335 or 336
- Shielded GU10 50W halogen bulbs (2 required for 30" and 36" hood widths, 3 required for 42" and 48" hood widths)
- RMP Series Backsplash (optional)
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)
- AEE Series Decorative flue, to be installed over the hood (optional)
- Transitions, duct, elbows, dampers, wall and roof caps.
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
-6-

Advertisement

Table of Contents
loading

This manual is also suitable for:

E6048tss

Table of Contents