Broan Quiet Hood QT20000 SERIES Installation Instructions Manual

Broan Quiet Hood QT20000 SERIES Installation Instructions Manual

Hide thumbs Also See for Quiet Hood QT20000 SERIES:

Advertisement

Available languages

Available languages

BROAN
iNSTALLATiON
INSTRUCTIONS
READ & SAVE THESE
iNSTRUCTiONS!
Quiet
OO
TM
QT20000 SERIES
iNTENDED FOR DOMESTIC COOKING ONLY
iMPORTANT
SAFETY
iNSTRUCTiONS
WARNING
- TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR
iNJURYTO
PERSONS,
OBSERVE
THE FOLLOWING:
1.
Use this unit only in the manner intended by the manufacturer,
tf you
have questions,
contact
the manufacturer
at the address
or tele-
phone number listed in the warranty.
2.
Before servicing
or cleaning
unit, switch power off at service panel
and lock service
panel to prevent
power from being switched
on
accidentally. When the service disconnecting
means cannot be locked,
securely
fasten a prominent
warning
device, such as a tag, to the
service panel.
3.
Installation
work and electrical
wiring must be done by a qualified
person(s)
in accordance
with all applicable
codes and standards,
including
fire-rated construction
codes and standards.
4.
Sufficient air is needed for proper combustion and exhausting of gases
through
the flue (chimney)
of fuel burning
equipment
to prevent
backdrafting.
Follow the heating equipment
manufacturer's
guideline
and safety standards
such as those published
by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local
code authorities.
5.
When cutting or drilling into wall or ceiling, do not damage
electrical
wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
Use with approved
cord-connection
kit only.
8.
To reduce the risk of fire, use only metal ductwork.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1.
Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
2.
Always turn hood ON when cooking
at high heat or when cooking
flaming foods.
3.
Clean ventilating
fans frequently.
Grease should
not be allowed to
accumulate
on fan or filter.
4.
Use proper pan size. Always use cookware
appropriate
for the size
of the surface element.
TO REDUCE
THE RISK OF INJURY TO PERSONS
IN THE EVENT OF
A RANGE TOP GREASE
FIRE, OBSERVE
THE FOLLOWING*:
1.
SMOTHER
FLAMES
with a close-fitting
lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. tf
the flames do not go out immediately,
EVACUATE
AND CALL THE
FIRE DEPARTMENT.
2.
NEVER PtCK UP A FLAMING
PAN - You may be burned.
3.
DO NOT USE WATER, including
wet dishcloths or towels - a violent
steam explosion will result.
4.
Use an extinguisher
ONLY if:
A. You know you have a Class ABC extinguisher,
and you already
know how to operate it.
B. The fire is small and contained
in the area where it started.
C. The fire department
is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Firesafety Tips" published
by NFPA.
IMPORTANT
SAFETY
INSTRUCTIONS
1.
For general ventilating
use only. Do not use to exhaust hazardous or
explosive
materials
and vapors.
2.
To reduce the risk of fire or electrical
shock, this range hood should
not be used with an additional speed control device.
3.
To reduce the risk of shock, disconnect
power before servicing.
4.
To reduce the risk of fire and to properly exhaust air, be sure to duct
air outside.
PLAN THE INSTALLATION
Recommended
mounting height is 18" to 24" from the bottom of the range
hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall cabinet. If
the hood must be mounted directly to a wall, secure the hood to wall studs.
All wiring must comply
with local codes and the unit must be properly
grounded.
The hood is connected
to a 110-120vAC
lighting circuit (15
amp) in the circuit breaker or fuse box.
This range hood is "Convertible"
- it may be installed as a ducted or as a
non-ducted
unit.
IF THE RANGE
HOOD
IS TO BE NON=DUCTED:
Purchase
non-ducted
(duct-free)
charcoal
filter Model BPQTF.
IF THE RANGE
HOOD
IS TO BE DUCTED:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge
on the hood.
For 7" round ductwork installation, use 7" round damper, Model BP87
(purchased
separately).

Advertisement

Table of Contents
loading

Summary of Contents for Broan Quiet Hood QT20000 SERIES

  • Page 1 BROAN iNSTALLATiON INSTRUCTIONS READ & SAVE THESE iNSTRUCTiONS! Quiet QT20000 SERIES iNTENDED FOR DOMESTIC COOKING ONLY iMPORTANT SAFETY iNSTRUCTiONS IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR For general ventilating use only. Do not use to exhaust hazardous or...
  • Page 2 HORIZONTAL DISCHARGE THROUGH WALL WALL CUTOUT DIMENSIONS KITCHEN CABINET WALL CAP SUPPLIED DUCT (MODEL 639 TRANSITION or 649) RANGE HOOD WIRING CUTOUT FIGURE 1 VERTICAL DISCHARGE USING 3%" x 10" DUCT CUTOUT DIMENSIONS ,2To ELBOW (MODEL EAVE CAP VIEW 3W'x 10" 9"...
  • Page 3: Installation

    PREPARATION LOCATORS Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay BAFFLE PLATE out the range hood's mounting holes, wiring access and ductwork by marking the cabinet bottom and drywall where applicable. Make cutouts for wiring and ductwork. If the hood is to be ducted, install the ductwork so that is flush to the range hood's mounting surface.
  • Page 4: Wiring Connections

    WIRING CONNECTIONS All wiring connections must comply with local codes and the unit "U must be properly grounded. "U I"- Make sure box connector is secure. • Refer to FIGURE 8. Make wiring connections. IGREEN _ROUNDi GREEN Replace electrical box cover and secure with screw. •"r _SCREW_ OR BARE...
  • Page 5: Service Parts

    SERVICE PARTS KEY NO. PART NO. DESCRIPTION 99080532 Motor R531076 Fan Blade R99420635 External Hitch Pin (Hairpin) 99271236 Lamp Socket (2 Required) R99030319 Fan Switch Assembly R561138 Light Switch NTK4402-000 Rectifier Assembly (Night-Light) 97015294 Light Lens Assembly 98009816 Wiring Cover R99091033 Grille (Black) R99091034...
  • Page 6: Warranty

    LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or installation contrary to recommended installation instructions.
  • Page 7 BROAN INSTRUCCIONES DE INSTALACION iLEA Y GUARDE ESTAS INSTRUCCIONES! Quiet SERIE QT20000 PREVIST0PARA C0CiNAR DOMC:STiC0 SOLAMENTE, INSTRUCCIONES IMPORTANTES INSTRUCCIONES IMPORTANTES DE SEGURIDAD DE SEGURIDAD CUIDADO - PARA REDUCIR EL RIESGO DE FUEGO, DESCARGA NO USE AGUA, incluyendo trapos o toallas mojadas ya que el usar-...
  • Page 8 DESCARGA HORIZONTAL A TRAVES DE LA PARED PARED DIMENSIONES DE LA SALIDA ARMARIO TRANSICION DE COCINA PROVISTA PARA TAPA DE EL CONDUCTO PARED CAMPANA DE COCINA 1<--m_,84 ORIFICIO PARA 67 _ EL CABLEADO I_ 2_ FIGURA 1 TAPA E TECHO DESCARGA VERTICAL USANDO...
  • Page 9 PREPARACION LOCALIZADORES Use los dibujos dimensionales (FIGURAS 1 - 3) para disponer .-- PLACA los orificios de montaje de la campana, acceso det cabteado y DEFLECTORA conductos, marcando et fondo det armario y et tabique donde sea aplicable. Efecto e los cortes para et cableado y et conducto. Instale el conducto de manera que este al ras con la superficie de montaje de la campana de cocina, si la campana se conec- ta a un conducto.
  • Page 10: Mantenimiento

    CONEXIONES DE CABLEADO Todas las conexiones de cableado deben cumptir con et c6digo local y la unidad debe estar apropiadamente conectada a tierra. z_ BLANCO BLANCO Asegt_rese que et conector de la caja este bien asegurado. NEGRO NEGRO Refierase a la FIGURA 8. Efectt3e las conexiones det cableado. TORNILLO VERDE : VERDE O DECON FI_ON...
  • Page 11 PIEZAS DE SERVlCIO CODIGO NO. PIEZA DESCRIPCION 99080532 Motor R531076 Aspa det ventilador R99420635 Perno Sujetador Externo 99271236 Portalamparas (2 requeridos) R99030319 Ensamblado de interruptor det ventilador R561138 Interruptor para luz NTK4402-000 Ensamblado det rectificador (Luz nocturna 97015294 Ensamblado det lente de luz 98009816 Cubierta para el alambrado R99091033...
  • Page 12 LA OBLIGACION DE BROAN-NUTONE LLC DE REPARAR O REEMPLAZAR, SlGUIENDO EL CRITERIO DE BROAN-NUTONE LLC, DEBERA SER EL UNICO Y EXCLUSlVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA. BROAN-NUTONE LLC NO SERA RESPONSABLE POR DANOS INCIDENTALES, CONSlGUIENTES, O POR DANOS ESPEClALES...

Table of Contents