HP Z Series Maintenance And Service Manual page 86

Hide thumbs Also See for Z Series:
Table of Contents

Advertisement

Table 7-1
POST numeric codes and text messages (continued)
Control panel message
2E5-ECC Memory Module Detected on
Unsupported Platform
2E6–Memory Not Configured Correctly
for Proper MEBx Execution
300–Configuration Change Warning
301-Hard Disk 1: SMART Hard Drive
Detects Imminent Failure
302-Hard Disk 2: SMART Hard Drive
Detects Imminent Failure
309 – 30C: Hard Disk 3–6: SMART Hard
Drive Detects Imminent Failure
3F0–Boot Device Not Found
78
Chapter 7 POST error messages
Description
Recently added memory modules
support ECC memory error correction.
DIMM1 is not installed.
A change in storage configuration
has been detected (see Boot Options
menu in BIOS Setup to enable this
feature). Either the installed hardware
has changed, storage or firmware mode
may have been changed, or a storage
device may have failed to respond.
Hard drive is about to fail. (Some hard
drives have a hard drive firmware patch
that will fix an erroneous error message.)
Hard drive is about to fail. (Some hard
drives have a hard drive firmware patch
that will fix an erroneous error message.)
Hard drive is about to fail. (Some hard
drives have a hard drive firmware patch
that will fix an erroneous error message.)
Boot device not found.
Recommended action
1.
If additional memory was recently
added, remove it to see if the
problem remains.
2.
Check product documentation for
memory support information.
Make sure there is a memory module in
the DIMM1 socket and that it is properly
seated.
If no changes have been made prior
to this warning, check that the drives
are connected properly to power cables
and system board. User Diagnostics
during boot-up) may help identify any
problem with specific devices.
1.
Determine if hard drive is giving
correct error message. Run the
Drive Protection System test under
using F2 Diagnostics when booting
the computer.
2.
Apply hard drive firmware
patch if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard
drive.
1.
Determine if hard drive is giving
correct error message. Run the
Drive Protection System test under
using F2 Diagnostics when booting
the computer.
2.
Apply hard drive firmware
patch if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard
drive.
1.
Determine if hard drive is giving
correct error message. Run the
Drive Protection System test under
using F2 Diagnostics when booting
the computer.
2.
Apply hard drive firmware
patch if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard
drive.
Insert boot device or load operating
system.
(f2

Advertisement

Table of Contents
loading

Table of Contents