Troubleshooting – Hardware
If you face any hardware related issues involving the RS6614V/RS6618V Enclosure OR disk drives, refer to the
following sections for troubleshooting tips. For all other problems, submit a support.

Enclosure Mute Button

The mute button on the back will mute the alarm for enclosure related issues such as enclosure FAN or
TEMPERATURE failures.

LED Activity

The following information tells you how to interpret LED activity seen on the enclosure and disk trays.
Table 1. LED Status Information
LED Type
Power LED
Warning LED
Fail LED
UNLIT
Table 2. LED Diagrams
LED Location
Disk Tray Top LED
Interpretation
SOLID BLUE (Normal Status)
Unit is powered OFF
Disk tray is empty
Icon
SOLD BLUE: the disk tray is
occupied, but the disk is not in use
47
FLASH YELLOW. The enclosure's temperature
has exceeded the warning threshold 55℃ or
the fan speed is below normal operating levels
700rpm/min
SOLID RED. The temperature is greater than
60℃;
FLASH RED. The fan speed is less than 500
rpm/min, the red light is flashing, and
generates an audible alarm