Product Specifications

MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
(a)
Indoor Airflow (CFM)
Power Input (KW)
EER2/SEER2 BTU/Watt-Hr
Sound Power Rating [dB(A)]
(b)
PERFORMANCE HEATING
(c)
Input BTUH-1st Stage (Natural Gas)
AFUE
Temp. Rise -min/max (°F)
Orifice Qty/drill size (Nat Gas)
POWER CONN. — V/Ph/Hz
Min. Brch. Cir. Ampacity
(e)
Fuse Size — Max. (amps)
Fuse Size — Recmd. (amps)
COMPRESSOR
VOLTS/PH/HZ
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I
Face Area (sq. ft.)
Tube Size (in.)
INDOOR COIL — TYPE
Rows/F.P.I
Face Area (sq. ft.)
Tube Size (in.)
Refrigeration Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
DIA. (IN.)
DRIVE/NO. SPEEDS
CFM @ 0.0 in. w.g.
(f)
Motor — HP/R.P.M
Volts/Ph/Hz
F.L. Amps/L.R Amps
INDOOR FAN — TYPE
Dia. x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
(g)
Motor — HP / R.P.M.
Volts/Ph/Hz
COMBUSTION FAN-TYPE
Drive / no. Speeds
Motor- HP / R.P.M.
F.L. Amps
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft)
(h)
REFRIGERANT
Charge (lbs.)
Subcooling
(a)
Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B.67 W.B. entering air to indoor coil. 95 D. B. entering air to
outdoor coil.
(b)
Sound Power values are not adjusted for AHRI 270–95 tonal corrections.
(c)
Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
(d)
Convertible to LPG.
(e)
This value is approximate. For more precise value, see Unit Nameplate.
(f)
Standard Air — Dry Coil — Outdoor.
(g)
Based on U.S. Government Standard Tests.
(h)
Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer's recommendation with a clean resistance of 0.05" W.C.
18-EB40D1-1E-EN
4YCC4024*1
23200
785
66.6
(d)
30/60
2 / #37
13.2
2/16
2.7
0.81
2350
1/12 / 810
1/3 / 1050
1/34 /3345
4.0
10°
I I n n t t r r o o d d u u c c t t i i o o n n , , U U n n i i t t I I n n s s p p e e c c t t i i o o n n a a n n d d S S p p e e c c i i f f i i c c a a t t i i o o n n
4YCC4030*1
208–230/1/60
28000
880
LOCATED ON UNIT NAMEPLATE
11.00 / 13.40
70
LOCATED ON UNIT NAMEPLATE
81
30/60
2 / #33
208–230/1/60
LOCATED ON UNIT NAMEPLATE
LOCATED ON UNIT NAMEPLATE
LOCATED ON UNIT NAMEPLATE
SCROLL
208–230/1/60
LOCATED ON UNIT NAMEPLATE
SPINE FIN
2 / 24
13.3
3/8
MCHE
2/16
2.7
0.81
EXPANSION VALVE
3/4 FEMALE NPT
Swept
23.4
DIRECT / 1
2800
1/6 / 825
208–230/1/60
LOCATED ON UNIT NAMEPLATE
Const. Torque ECM
10.62 x 10.62
DIRECT / 4
SEE FAN PERFORMANCE TABLE
1/2 / 1050
208–230/1/60
Centrifugal
Direct 1
1/34 /3290
LOCATED ON UNIT NAMEPLATE
NO
THROWAWAY
4.0
R-410
LOCATED ON UNIT NAMEPLATE
4YCC4036*1070
[4YCC4036*1090]
36400
1215
69.3
30/60 [35/65]
2 / #33 [3 / #37]
15.5
2/16
2.7
1
3080
1/5 /825
3/4 / 1050
1/34 /3290
4.0
11°
5