MULTIQUIP QP4TB Operation Manual
MULTIQUIP QP4TB Operation Manual

MULTIQUIP QP4TB Operation Manual

Trash pump vanguard 400 25v3 14 hp gasoline engine

Advertisement

Quick Links

OPERATION MANUAL
MODEL
QP4TB
TRASH PUMP
(VANGUARD 400 25V3 14 HP GASOLINE ENGINE)
Revision #0 (01/11/24)
To find the latest revision of this publication or
associated parts manual, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.

Advertisement

Table of Contents
loading

Summary of Contents for MULTIQUIP QP4TB

  • Page 1 OPERATION MANUAL MODEL QP4TB TRASH PUMP (VANGUARD 400 25V3 14 HP GASOLINE ENGINE) Revision #0 (01/11/24) To find the latest revision of this publication or associated parts manual, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
  • Page 2: Proposition 65 Warning

    PROPOSITION 65 WARNING PAGE 2 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 3: Table Of Contents

    Components (Engine) ..........14 Inspection .............. 15 Setup ..............16 Operation ............17–19 Maintenance (Engine) ........20–22 Maintenance (Pump) ........24–26 Troubleshooting (Engine) ........27 Troubleshooting (Pump) ........28 QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 3...
  • Page 4: Safety Information

    COULD result in DEATH or SERIOUS INJURY. CAUTION Indicates a hazardous situation which, if not avoided, COULD result in MINOR or MODERATE INJURY. NOTICE Addresses practices not related to personal injury. PAGE 4 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 5 Also, know the phone numbers devices will void all warranties. of the nearest ambulance, doctor, and fi re department. This information will be invaluable in the case of an emergency. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 5...
  • Page 6 „ ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel. PAGE 6 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 7 Fire or explosion could result from fuel vapors or if fuel is spilled on a „ ALWAYS keep battery cables in good working condition. hot engine. Repair or replace all worn cables. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 7...
  • Page 8 „ Use a one-point suspension hook and lift straight upwards. „ DO NOT lift the machine to unnecessary heights. „ ALWAYS tie down equipment during transport by securing the equipment with rope. PAGE 8 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 9: Specifications

    92 ft. (28.0 m) Dry Net Weight 229 lb. (104 kg) Figure 1. QP4TB Dimensions Table 2. QP4TB Dimensions Reference Dimension Letter in. (mm) 28.1 (714) 25.0 (635) 27.9 (709) QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 9...
  • Page 10 TOTAL HEAD METERS FEET 23.3 FT 16.7 FT 10 FT 3.3 FT U.S. GALLONS PER MINUTE LITERS 1000 1500 2000 PER MINUTE Figure 2. QP4TB Performance Curve PAGE 10 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 11: General Information

    6,000 (1,828.8) 8,000 (2,438.4) 10,000 (3,048) ACCESSORIES Multiquip offers a complete line of fittings, hoses, and couplers for various pump applications. Contact the Multiquip Parts Department for more information. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 11...
  • Page 12: Components (Pump)

    COMPONENTS ( PUMP ) Figure 3 shows a typical QP4TB trash pump application. The main pump components are listed below. Figure 3. Pump Components PAGE 12 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 13 To open the cover, loosen the four locking knobs, grip the cover handles, and turn the cover counterclockwise. Once the cover is clear of the four knob fasteners, pull it outward to open. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 13...
  • Page 14: Components (Engine)

    11. Choke Lever — Aids in starting a cold engine or once a week. starting in cold weather conditions. The choke enriches the fuel mixture. 5. Throttle Lever — Adjusts engine speed (RPM). PAGE 14 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 15: Inspection

    ALWAYS use a strainer for filtration while refueling. correct oil level is at the top of the full indicator on the NEVER top off fuel. ALWAYS wipe up any spilled fuel dipstick. immediately. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 15...
  • Page 16: Setup

    Continued operation of the pump in this condition is not recommended, and can cause severe water damage to the engine. Figure 7. Pump Setup PAGE 16 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 17: Operation

    Severe damage will LEVER occur to the pump’s mechanical seal if the pump has not been primed. CLOSE OPEN Figure 9. Choke Lever (Closed) QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 17...
  • Page 18 If the engine has not started, repeat steps 1–5. 6. Run the engine at idle for several minutes and check for any abnormal conditions such as extreme vibration, loose components, or fluid leaks. PAGE 18 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 19 Figure 14. Engine Throttle Lever (OFF) NOTICE When transporting the pump, ALWAYS turn off the engine fuel valve by placing the engine throttle lever in the OFF position. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 19...
  • Page 20: Maintenance (Engine)

    (1) In dusty conditions or when airborne debris is present, clean more often. (2) Not required unless engine performance problems are noted. (3) For commercial use, log hours of operation to determine proper maintenance intervals. PAGE 20 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 21 NOTICE Operating the engine with loose or damaged air cleaner components can allow unfiltered air into the engine, causing premature wear and failure. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 21...
  • Page 22 Table 6. Maximum engine oil capacity is 1.0 quarts (0.95 liters). DO NOT overfill. 6. After adding oil, wait one minute and then check the oil level. PAGE 22 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 23 NOTES QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 23...
  • Page 24: Maintenance (Pump)

    This prevents backflow and allows for faster priming when the engine is restarted. PAGE 24 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 25 INTO 25 FEET OF LIFT SHOULD BE BETWEEN -100 AT SEA LEVEL. -25 AND -20 IN. HG. in. Hg WIKA PUMP VACUUM TESTER Figure 19. Pump Vacuum Test QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 25...
  • Page 26 „ Cover the pump and engine with a plastic sheet and store them out of direct sunlight, in a location that is free of moisture and dust. PAGE 26 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 27: Troubleshooting (Engine)

    Check fuel line. Air taken in through suction line? Check suction line. Dust in rotating part? Clean recoil starter assembly. Recoil starter not working properly. Spring failure? Replace spiral spring. QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 27...
  • Page 28: Troubleshooting (Pump)

    Impeller does not turn, pump Adjust clearance by removing shim from Impeller and volute binding? is hard to start. behind impeller. Defective engine? See engine owner’s manual. PAGE 28 — QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)
  • Page 29 NOTES QP4TB TRASH PUMP • OPERATION MANUAL — REV. #0 (01/11/24)— PAGE 29...
  • Page 30 © COPYRIGHT 2024, MULTIQUIP INC. Multiquip Inc , the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.

Table of Contents