Ip66 remote keypad

Advertisement

Connection and Operation (continued)
For multiple base units connected to the keypad, the use of VMX-AGY-011, VMX-AGY-036 and VMX-AGY-035
(terminator) is highly recommended. See diagram below.
(supplies power to VMX-AGY-012)
The VMX-agility
Parity/Baud rate values on each unit

Operation

Once connected to the VMX-agility
TM
in the VMX-agility
manuals MAN-AGY-015 and MAN-AGY-014 (both may be downloaded from
www.motortronics-uk.co.uk).
However, specific steps must be taken to connect the Remote Keypad to one or more VMX-agility
Initial Power-Up
TM
If the host VMX-agility
unit/s and the remote keypad have the default Modbus transmission parameters set,
and the host unit is powered and has Keypad power set to 'on', the keypad will automatically communicate with
the host. The following status screen will be seen:
Motor Overload level
(Local, Remote, Modbus)
MAN-AGY-023 Version 01
Close Jumper S6
VMX-AGY-011
Enable keypad
power
on this unit
only
Address = 1
TM
units must have: a unique Modbus address on each unit and identical
TM
host unit/s, menu structures and programming are the same as detailed
Control method
VMX-AGY-036
Address = 2
Status of connected host
Navigation Wizard
(displays 'active' keys)
Modbus address
of connected unit
4
VMX-AGY-035
(last unit only)
Address = 3
TM
host units.