30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with an Electric Oven and a Gas Cooktop)
Terminal Block
Silver Colored
Black wire———
1-1/8" Dia. —4
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
s
(Bare Copper
or Green
Wire)
A strainrelief
supplied by the user
must be installed at
To 240 V receptacle
this location
NOTE:
Be sure to remove the supplied
f
grounding strap
——mr
Figure 4
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 4) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 5):
(The 3-conductor cord or cable must be replaced with
a 4-conductor cord or cable where grounding through
the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box
connect the appliance and residence cable wires as
shown in figure 5.
Cable from
Residence
White Wire
(Neutral)
i#———
Junction
Box
Oe
White Wire
~
(Neutral)
Green
i
U.L.-listed
(or Bare Copper)
ms
Conduit
Wire
Cable from
Connector
Range
(or CSA listed)
Figure 5
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 6):
1.
Disconnect the power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
Inthe circuit breaker, fuse box or junction box:
connect appliance and residence cable wires as
shown in figure 6.
Cable from
Green
Residence
(or Bare Copper)
Junction
Box
So
4
White Wire
.
(Neutral)
Green
:
(or Bare Copper)
(TS.
White Wire
Wire
a,
(Neutral)
3
U.Llisted
Cable from
Conduit
Appliance
Connector
(or CSA listed)
Figure 6 - 4-Wire Electrical System
(Example: Junction Box)