Mitsubishi Electric SUZ-SWM30VA TH Series Service Manual page 41

Outdoor/indoor unit hfc utilized r32
Table of Contents

Advertisement

OPERATING PROCEDURE
2. Removing the inverter assembly and inverter P.C.
board
(1) Remove the cabinet and panels (refer to section 1).
(2) Disconnect the lead wire to the reactor and the following
connectors:
<Inverter P.C. board>
CN721 (R.V. coil)
CN931, CN932 (Fan motor)
CN641 (Defrost thermistor and discharge temperature ther-
mistor)
CN643 (Ambient temperature thermistor)
CN644 (Outdoor heat exchanger temperature thermistor)
CN724 (LEV)
CN722 (Defrost heater and heater protector)
CN64 (Compressor protector)
(3) Remove the compressor connector (CN61).
(4) Remove the screws fixing the heat sink support and the
separator.
(5) Remove the fixing screw of the P.B. support and the separator.
(6) Remove the fixing screws of the terminal block support and
the back panel.
(7) Remove the inverter assembly.
(8) Remove the screws of the earth wires.
(9) Remove the heat sink support from the P.C. board support.
(10) Remove the screw of the inverter P.C. board and remove the
inverter P.C. board from the P.C. board support.
*
Connection procedure when attaching the inverter P.C.
board (Photo 4)
1. Connect the lead wires of the heat exchanger temperature
thermistor, the defrost thermistor and discharge tempera-
ture thermistor to the connector on the inverter P.C. board.
Pull the lead wires toward you and put them on the right
hook on the P.C. board support.
2. Connect the lead wires of the LEV to the connector on the
inverter P.C. board. Pull the lead wires toward you and put
them on the right hook on the P.C. board support.
3. Connect the lead wires of the ambient temperature ther-
mistor to the connector on the inverter P.C. board. Pull
the lead wires toward you and put them on the left hook
on the P.C. board support so that the fan motor lead wires
are bundled up as shown in Photo 4.
4. Hook the lead wires of the defrost heater and the heater
protector. (Photo 5)
Photo 5
OCH796A
Photo 3
Screw of the heat sink
support and the separator
Photo 4
Lead wires of
the ambient
temperature
thermistor
Inverter P.C. board support
Lead wires of the
defrost heater
Photo 6 (Inverter assembly)
Heat sink
Inverter P.C. board
41
PHOTOS/FIGURES
Lead wires of the heat
exchanger temperature,
defrost and discharge
temperature thermistor
Heat sink support
Screw of the inverter P.C. board
Screw of the P.B. support
and the separator
Screws of
the terminal block
support and
the back panel
Lead wires of
the LEV
Connector of
compressor protector
P.C. board support
Screws of
the earth wire

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents