Rack Installation

(FNC-CA-500F)
The supplied equipment is designed for standard 19inch racks. The rails
provided are specially designed for this model.
Rack Stability
Ensure the rack is stable before installing the slide rails and appliance.
Check that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on the
jacks
For single rack installation, stabilizers should be attached to the rack;
for multiple rack installations, the racks should be coupled together
Appliance Installation
To avoid personal injury or equipment damage, use a lifting device
Do not pick up the appliance by the front handles
Each inner rail has a system lock out tab to prevent the appliance from
sliding out, ensure that it is locked when installing the appliance
Prevent Electrostatic discharge (ESD) damage by wearing antistatic
devices
Do not place heavy objects on the appliance
What You Will Need
Philips screwdriver, level & tape measure
Rack-provided cage nuts and screws
A lifting device or additional support
ESD antistatic gear
8
Rail Assembly
The rail kit includes a left and a right rail assembly
Each rail assembly includes an inner rail, a middle rail, and an outer rail
The inner rail has locking keyholes used to secure the rail to the
appliance
The inner rail rear end has a lock out tab which slides into the middle rail
The middle rail is in the outer rail and used to guide the inner rail into
the outer rail
The outer rail has front and rear mounting pins that push into to the
rack holes
The outer rail also has front and rear locking latches to secure the rail to
the rack
Locking Latch
Lock Out Tab
Outer Rails
Inner Rails
Release Tab
Mounting Pins
Locking Keyhole
9