Insignia BestBuy NS-46E570A11 Service Manual page 29

Hide thumbs Also See for BestBuy NS-46E570A11:
Table of Contents

Advertisement

46"LCD TV
4. Input Source
select for which input source wants to do the Standard Mode resetting.
5. Color Temperature
The select items: Warm, Normal and Cool.
6. Adaptive Contrast
The select items: On/Off (Default is Off).
7. DCR
Select for the Standard Mode DCR preset setting in selected source.
The select items: On/Off (Default is Off).
8. MEMC
Not available in Insignia models.
9. Back Light Set Backlight preset value for the Standard Mode in selected source.
The adjust range is 0 ~ 30 (default 30)
10. Brightness Set Brightness preset value for the Standard Mode in selected source.
The adjust range is 0 ~ 100 (default 50)
11. Contrast
Set Contrast preset value for the Standard Mode in selected source.
The adjust range is 0 ~ 100 (default 50)
12. Color
Set Color preset value for the Standard Mode in selected source.
The adjust range is 0 ~ 100 (default 60)
13. Tint
Set Tint preset value for the Standard Mode in selected source.
The adjust range is R50 ~ G50 (default 0)
14. Sharpness
Set Sharpness preset value for the Standard Mode in selected source.
The adjust range is -50 ~ +50 (default 0)
15. Set Geometry
Select the ratio of TV Screen Overscan for all input and timing.
Once service man changed Geometry setting from Normal to Overscan = 0% or 8%, then below three items is
needs:
a. All input and all picture mode Geometry will also setting to service menu new setting value.
b. The Overscan menu in OSD will be disabled (Gray out).
c. The all aspect ratio Overscan will same as the new Overscan setting.
16. Reset to Factory Setting
17. Exit
Close the exit the Service Menu.
Select for the Standard Mode color temp. preset value in selected source.
Select for the Standard Mode Adaptive Contrast preset setting in selected source.
Set all service menu items to default value for all input source.
29