GE PGP953 Installation Instructions Manual page 6

30” sealed gas cooktop
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions
INSTALLATION—GAS CONNECTIONS
[4] PROVIDE ADEQUATE GAS SUPPLY
This cooktop is designed to operate on natural
gas at 5" of water column manifold pressure and
7" of water column (W.C.) supply pressure. It is
shipped from the factory set for natural gas. The
convertible pressure regulator supplied with the
unit must be connected in series with the manifold
of the cooktop and must remain in series with the
supply line regardless of whether natural or L.P.
gas is being used. FOR PROPER OPERATION, THE
MAXIMUM INLET PRESSURE TO THE REGULATOR
MUST BE NO MORE THAN 14" OF WATER COLUMN
PRESSURE. For checking the regulator, the inlet
pressure must be at least 1" W.C.. {or 3.4 KPA)
greater than the regulator output setting. If
the regulator is set for 5" W.C. of water column
If the regulator is set for 10" W.C., the inlet pressure
must be at least 11" W.C.. The gas supply line to
the cooktop should be 1/2" or 3/4" pipe.
pressure, the inlet pressure must be at least 6" W.C.
[3] INSTALL REGULATOR ONTO
BURNER BOX BOTTOM
Screw the regulator
]
onto the burner
=
box bottom pipe
connection. Make
sure the top of
the regulator is
facing towards the
cabinet front, easily
Pressure
Regulator
Coupling —— ff
h
accessible through
Shut-off
\ clectrical
the cabinet doors.
Outlet 12"
The regulator may
Below
Countertop
also be installed
prior to inserting
the cooktop into the cutout if extreme caution is
used to ensure the regulator connection is not
compromised.
[2] INSTALL REGULATOR
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
AWARN
ING:
Never reuse old flexible
connectors. The use of old flexible connectors
can cause gas leaks and personal injury. Always
use new flexible connectors when installing a gas
appliance.
.
.
Pressure
Screw a section of pipe onto
Regulator
4
the inlet end of the pressure
regulator and install the
coupling.
Coupling
To reduce the likelihood of gas leaks, applytetton
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
[4] COMPLETE CONNECTION WITH A
COUPLING
Complete the
connection between
the regulator, pipe
coupling, and
the shut-off valve.
Pressure ——={f |]
Regulator
N Shut-off —_-off
qi?
\
Electrical
Outlet 12"
Below
Countertop

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pgp959Cgp350

Table of Contents