General Venting Information; Termination Location - Majestic VERMONT Castings RFSDV34 Installation Instructions & Homeowner's Manual

Freestanding direct vent fireplace
Table of Contents

Advertisement

,ur fireplace is approved to be vented either through the side
all, or vertically through the roof.
Only venting components specifically approved and labelled
for this fireplace may be used.
Minimum clearances between vent pipes and combustible
materials is one (l ") inch (25 mm).
Venting terminals shall not be recessed into a wall or
siding.
Horizontal venting must be installed on a level plane without
any incline or decline.
There must not be
l!l1)(
obstruction such as bushes, garden sheds,
fences, decks or utility buildings within 24" from the front
of the termination hood.
-
.
-F-jyjI
:
r
i:c::-,"
►lBI-,,.
IS1]
TERMINATION CAP
@
AIR SUPPLY INLET
A
=
clearance above grade, veranda, porch, deck, or balcony
[* 12 inches (305mm) minimum]
B
=
clearance lo window or door that may be opened 12"
(306mm).
C
=
clearance to permanently closed window [minimum 12
inches (305mm) recommended to prevent condensation
on window]
D
=
vertical clearance to ventilated soffit located above
the terminal/ within a horizontal distance of 24 inches
(610mm)from the centre-line of the terminal [18 inches
(458mm) minimum}
E
=
clearance to unventilated sojfit [J 2 inches (305mm)
minimum
F
=
clearance to outside corner see next page
G
=
clearance to inside corner see next page
H
=
*
not to be installed above a meter/regulator assembly
within 36 inches (9 l 4mm)horizontally from the centre-line
of the regulator
Do not locate termination hood where excessive snow or ice
build up may occur. Be sure to check vent termination area
after snow falls, and clear to prevent accidental blockage of
venting systern. When using snow blowers, make sure snow is
not directed towards vent termination area.
Location of Vent Termination
It is imperative that the vent termination be located observing
the minimum clearances as shown on this page.
*Check with local codes or in absence of same with CANICGA Bl49
(. I or .2) Installation Codes (1991) for Canada or for U.S.A. Installa-
tions follow the current National Fuel Gas Code, ANSI 2223.1.
riJGASMETER
[[j
RESTRICTED AREA
(TERMINATION PROHIBITED)
I=
clearance to service regulator vent outlet [*72 inches
(I 828mm) minimum}
J
=
clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other fireplace [ • 12
inches (305mm) minimum}
K
=
clearance to
ti
mechanical air supply inlet [* 72 inches
(I 82 8mm) minimum
J
L
=
f
clearance above paved side-walk or a paved driveway
located on public property [*84 inches (2 I 33mm)
minimum}
M
=
clearance under veranda, porch, deck [* 12 inches
(305mm) minimum!}
N
=
Clearance above a roof shall extend a minimum of 24"
(610mm) above the highest point when it passes through
the roof swface, and any other obstruction within a
horizontal distance of 18" (450mm).
f
a vent shall not terminate directly above a side-walk or paved driveway which is located between two single
family dwellings and serves both dwellings
*
f
only permitted if veranda, porch, deck, is fully open on a minimum 2 sides beneath the floor •
as specified in CANICGA Bl 4§ ( I or .2) Installation Codes (I 99 I) for Canada or for U.S.A. Installations follow
the current National Fuel Gas Code, ANSI Z223.J.
Note: Local codes or regulations may require different clearances.
10001948/1 -Page 7 -