Samsung AM CNB C AA Series Technical Data Book page 14

Table of Contents

Advertisement

4. Capacity Table
Hydro Unit HT
8TON DVM S TDB Heat Capacity Table
Combination,%
(Capacity index)
100%
Combination 1 ( Outdoor Unit 8TON + Indoor Unit 4TON x 2ea)
Indoor Heat Capa.[kW]
Indoor Heat Capa.[kW]
PI Indoor Unit(4TON)[kW]
PI Total Indoor Unit[kW]
PI Outdoor Unit(8TON)[kW]
PI System[kW]
Flowrate Information
Flowrate[gpm]
ΔT = 27℉
ΔT = 18℉
ΔT = 9℉
Outdoor Temperature(℉)
DB
-4
1
5
10
14
19
23
27
32
37
41
45
48
52
55
59
54,500
= HT Capacity Table (Ref. P.17)
109,000
= 2 x 5HP
= HT Capacity Table (Ref. P.17)
2.419
4.838
= 2 x 5HP
6.70
11.54
= Total Indoor Unit PI + Outdoor Unit PI
**048**
**072**
4.1
6.4
6.1
9.5
12.2
19.0
Indoor Temperature(℉,DB)
TC
WB
Btu/h
-6
90,422
0
95,881
3
99,293
9
101,341
12
104,753
18
106,459
21
107,482
25
107,482
30
107,482
36
107,482
39
107,482
43
107,482
46
107,482
50
107,482
54
107,482
57
107,482
68℉
PI
kW
10.24
10.45
10.67
10.62
10.4
9.57
8.99
8.15
7.68
7.25
6.88
6.7
6.38
6.08
5.81
5.61
Outdoor Unit Capacity Table

Advertisement

Table of Contents
loading

Table of Contents