Install Cable
that the bend radius for fiber optic cables is equal to at least 5 cm (2 in) for each
90-degree turn as shown in
Note
Kinks and sharp bends can destroy or impair the cable's ability to convey light
pulses accurately from one end of the cable to the other. Use care in dressing
the optical fiber cables: provide satisfactory strain relief to support the cable
and maintain an adequate bend radius at all cable turns, particularly where the
cable connects to the I/O module.
Figure 31: Bend Radius for Fiber Optic Cable
1 = Minimum 5 cm (2 in) radius in 90° bend
Cable Distances and Types
Table 11
shows one example of cable media types and maximum distances that support
reliable transmission in accordance with international standards (except where noted).
Refer to the
as a complete list of supported cable lengths, and a list of the cable types that are
compatible with your equipment.
Table 11: Cable Distances and Types
Standard
1000BASE-SX
(850nm optical window)
48
ExtremeSwitching 5420 Series Hardware Installation Guide
Figure
Extreme Optics
website for descriptions of optics and cables, as well
Media Type
50/125 µm multimode fiber
50/125 µm multimode fiber
62.5/125 µm multimode fiber
62.5/125 µm multimode fiber
31.
Site Preparation
MHz•km
Maximum
Rating
Distance (Meters)
400
500
500
550
160
220
200
275