External display support

The following table lists the external display support for your Alienware x16 R2.
Table 22. External display support 
Graphics card
Intel Arc Graphics
NVIDIA GeForce RTX 4080

Operating and storage environment

This table lists the operating and storage specifications of your Alienware x16 R2.
Airborne contaminant level: G1 as defined by ISA-S71.04-1985
Table 23. Computer environment 
Description
Temperature range
Relative humidity (maximum)
*
Vibration (maximum)
Shock (maximum)
Altitude range
CAUTION: Operating and storage temperature ranges may differ among components, so operating or storing the device
outside these ranges may impact the performance of specific components.
* Measured using a random vibration spectrum that simulates the user environment.
† Measured using a 2 ms half-sine pulse.

Dell low blue light display

WARNING: Prolonged exposure to blue light from the display may lead to long-term effects such as eye strain, eye fatigue,
or damage to the eyes.
Blue light is a color in the light spectrum which has a short wavelength and high energy. Chronic exposure to blue light, particularly
from digital sources may disrupt sleep patterns and cause long-term effects such as eye strain, eye fatigue, or damage to the eyes.
The display on this computer is designed to minimize blue light and complies with TÜV Rheinland's requirement for low blue light
displays.
Low blue light mode is enabled at the factory, so no further configuration is necessary.
To reduce the risk of eye strain, it is also recommended that you:
● Position the display at a comfortable viewing distance between 20 and 28 inches (50 cm and 70 cm) from your eyes.
● Blink frequently to moisten your eyes, wet your eyes with water, or apply suitable eye drops.
● Look away from your display, and gaze at a distant object at 20 ft (609.60 cm) away for at least 20 seconds during each break.
● Take an extended break for 20 minutes every two hours.
Supported external displays with laptop
display enabled
2
2
Operating
0°C to 35°C (32°F to 95°F)
10% to 90% (non-condensing)
0.66 GRMS
110 G†
-15.2 m to 3048 m (-49.87 ft to 10000
ft)
Supported external displays with laptop
display disabled
2
2
Storage
-40°C to 65°C (-40°F to 149°F)
0% to 95% (non-condensing)
1.30 GRMS
160 G†
-15.2 m to 10668 m (-49.87 ft to 35000
ft)