OPERATION
DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks
outdoors over bare ground.
DO NOT overfill fuel tank. Wipe up spills immediately.
Securely tighten fuel tank cap and close fuel container
after refueling.
Inspect for fuel leakage. If fuel leakage is found, do not
start or operate unit until leakage is repaired.
Use caution when handling fuel. Mix and pour fuel
outdoors where there are no sparks and flames. Slowly
remove the fuel cap only after stopping the engine and
allowing the unit to cool. Do not smoke while fueling or
mixing fuel. Move the unit at least 10 feet (3 m) from the
fueling point before starting the engine.
Gasoline vapor is heavier than air, and can travel along the
ground to nearby sources of ignition such as electrical motors,
pilot lights, and hot or running engines. Vapors ignited by an
ignition source can flash back to the fuel container, resulting in
an explosion, fire, serious or fatal injuries, and extensive
property damage.
Mixing Instructions
Stored fuel ages. Do not mix more fuel than you expect to use in 30
days, 90 days when a fuel stabilizer is added.
1.
Fill an approved fuel container
with half of the required
amount of gasoline.
2.
Add the proper amount of
2-stroke oil to gasoline.
3.
Close container and shake to
mix oil with gasoline.
4.
Add remaining gasoline, close
fuel container, and remix.
22
Fuel to Oil Mix – 50:1 Ratio
US
Gas
Oil
gal.
fl.oz.
1
2.6
2
5.2
5
13
© 10/23 ECHO Incorporated
PB-265LN
Metric
Gas
Oil
L
cc
5
100
10
200
25
500
X7531181900