7. Operation and Functions
7-5. Error Mode
INPUT
- Error
CONTENTS
A. Error Display
Priorities
Error Code
1
R1
2
RT
3
D1
4
DR
5
C1
6
F3
※ All the error codes are reset if they turn to be normal.
B. Control way of Error (if any)
1) "R1" error
• Cause : R-Sensor disconnection or short
• Check Point :
- Measure the voltage between terminal PIN 7 and 8
after separating CN5 on the Main PCB.
- If the sensor is disconnected, the voltage is under 0.5V. Change the sensor.
- If the sensor is shorted, the voltage is over 4V. Change the sensor.
2) "RT" error
• Cause : RT-Sensor disconnection or short
• Check Point :
- Measure the voltage between terminal PIN 1 and 2
after separating CN4 on the Main PCB.
- If the sensor is disconnected, the voltage is under 0.5V. Change the sensor.
- If the sensor is shorted, the voltage is over 4V. Change the sensor.
CONTROL OBJECT
- LED LAMP on Main PCB
Main PCB LED
R-Sensor disconnection
Flickering 1 time
or short
RT-Sensor disconnection
Flickering 2 times
or short
D-Sensor disconnection
Flickering 3 times
or short
Sensing door open
Flickering 4 times
for more than 1hr
compressor runs over 3hr
Flickering 6 times
when D-Sensor temp. ≥ -5℃
Defrosting return is done
Flickering 7 times
by time limit
16
REMARKS