Pentair LINCOLN SYSTEM SENTRY 84530 Owner's/Operator's Manual page 4

Sensor controller - internal scan

Advertisement

11)
Determines
the number
of fault
cycles
(maximum
of 99)
that
can
occur
before
an alarm
NUMBER
OF
FAULT
CYCLES.
2
<
SET
>
First Button - Increments
the number
of fault
cycles
by one
<
- Decrements
the number
of fault
cycles
by one
SET - Stores
the
number
of
fault
cycles
displayed
on
screen
>
- Next
screen
Press
first
button
until
a "2"
appears.
Press
button
under
"SET".
Press
button
under
">".
12)
When
programming
IS complete,
set
internal
jumper
pin
to the
Run
position
WARNING:
Turn
power
off
before
opening
enclosure
door
to move
jumper
pin.
JUMPER IN
JUMPER IN
"PROGRAM"
POSITION
"RUN"
POSITION
RUN
MODE
To access
the Run Mode
the internal
jumper
must
be in the
Run position
WARNING:
Turn
power
off
before
opening
enclosure
door
to move
jumper
pin.
If no pushbuttons
are pressed
within
30 seconds,
whale in the
Main
Menu
options,
the controller
wiII enter
the RUN MODE
The following
screens
can appear
when
in the
Run Mode
Main
Menu
Options
MAIN
MENU
PLEASE
SELECT
Indicates
the number
of lube
events
that
have
taken
place
at each
sensor
Example
screen
below
shows
that 20 lube
events
have
taken
place
at sensor
number
1 There
are
sixteen
separate
counters,
one for each
sensor
When lube
passes
the sensor its
corresponding
counter
will Increment
by one
When
turning
power
on to the
controller,
the
sensors
will
warm
and
the
counters
may
increment
by one.
# OF
LUBE
EVENTS:
20
RESET
<
SNSR
1
RESET -
Pressing
the
corresponding
button
wiII
reset
all
sensor
counters
to zero
<
- Previous
screen
SNSR
1- Pressing
the corresponding
button
wiII display
the
active
sensors
in ascending
order
At the
same
time,
line
one
wiII
indicate
the
number
of lube
events
for the corresponding
sensor
on line two
ALARM
MESSAGES:
The
following
alarm
messages
can
appear
if
an
alarm
condition
occurs
Indicates
that the sensor
number
appearing
did not receive
lubricant
Alarm
relay
contact
will
close
and
red
light
on
door
will
turn
on
NO
LUBE
FLOW
SENSOR"
1
NEXT
SENSOR
NEXT -
Indicates
that there
IS more than one alarm
message
Pressing
the
corresponding
button
wiII
display
the
next
alarm
message
SENSOR -
Pressing
the corresponding
button
will cause
the
sensor
number
on line one to increment
to the next
sensor
with
the same
fault
Indicates
that
the
wire
running
to
the
sensor
number
appearing
has
opened
Red
light
on door
turns
on
BROKEN
WIRE
SENSOR
1
SETUP
REVIEW
RUN
NEXT
SENSOR
SETUP -
All programming
options
are available
in the Setup
Menu
REVIEW
- Can review
all system
parameters
that
have been
programmed
in the Setup
Menu
RUN - Controller
will
function
as it was
programmed
in the
Setup
Menu
Indicates
the
amount
of
time
remaining
in
the
scan
period
SCAN
TIME
LEFT
30
MIN
SENSOR
MENU
SENSOR
- Pressing
the corresponding
button
wiII cause
the
Sensor
screen
to appear
MENU
- Pressing
the
corresponding
button
wiII
cause
the
Main
Menu
to appear
4
NEXT - Indicates
that there
IS more than one alarm
message
Pressing
the
corresponding
button
wiII
display
the
next alarm
message
SENSOR
- Pressing
the corresponding
button
wiII cause
the
sensor
number
on Iine one to increment
to the next
sensor
with
the same
fault
Indicates
that
the
wire
running
to
the
sensor
number
appearing
has
shorted
Red
light
on door
turns
on
SHORTED
WIRE
SENSOR
1
NEXT
SENSOR
NEXT - Indicates
that there
IS more than one alarm
message
Pressing
the
corresponding
button
wiII display
the
next alarm
message
SENSOR
- Pressing
the corresponding
button
wiII cause
the
sensor
number
on line one to Increment
to the next
sensor
with
the same
fault