Pentair LINCOLN SYSTEM SENTRY 84530 Owner's/Operator's Manual page 3

Sensor controller - internal scan

Advertisement

5) Determines
if this
IS a Lube
& Sensor
controller.
LUBE
& SENSOR
CONTROL
?
YES
NO
<
YES - The controller
wiII function
as both
a Lube
& Sensor
controller
(refer
to
Centro-Matic
or
Modular
Lube
Manuals
for information
on Lube
programming).
NO - Sensor
controller
only
<
- Previous
screen.
Press
button
under
"NO".
6) Confirms
that
this
IS only
a Sensor
Controller
SENSOR
CONTROL
ONLY
?
YES
NO
<
YES - Confirms
that
this
IS only
a Sensor
Controller.
NO - Returns
to the "USING
SENSORS
?" display.
<
- Previous
screen
Press
button
under
"YES".
7) Determines
if an external
signal,
either a
contact
closure
at terminal
strip
B terminals
15 & 16 or 120/230
VAC at
terminal
strip
A terminals
5 & 6, wiII
initiate
a scan
period
EXTERNAL
INPUT
FOR
SCAN
YES
NO
YES - External
signal
will
initiate
a scan
period.
(Refer
to
Sensor
Controller
- External
Scan
Manual)
NO - Internal
scan
timer
wiII initiate
a scan
period
Press
button
under
"NO".
8) Sets
the amount
of time
for the
Internal
Scan
Timer
SCAN
TIME
30
MIN
3
0
X1
SET
Pressing
either
of the first two buttons
wiII Increment
number
above
it by one
First Two Buttons -
Determines
the
first
two
digits
of the
Scan
Time
Third
Button
- A multiplier
for the first two digits
X1
Multiplies
first two digits by 1
Range
1 to
99 min
X10
Multiplies
first two digits
by 10
Range
10 to
990 min
X100 Multiplies
first two digits
by 100
Range
100 to 9900
min
SET - Stores
value
displayed
on screen
Press
first
button
until
a 3 appears.
Press
second
button
until
a0
appears.
Press
third
button
until
an X1 appears.
Press
button
under
"SET"
to input
30 min.
9) Activates
sensor
inputs
one
thru
sixteen.
ACTIVATE
SENSOR
INPUTS
1
YES
NO
>
Pressing
the
first
it by one
button
wiII
increment
the
number
above
First
Button
- Determines
sensor
input
number,
1 thru
16.
YES - Pressing
this button
indicates
that a sensor
IS connected
to the sensor
terminals
that correspond
with the sensor
input
number
above
the
first
button
(see
Field
Connections).
NO - Pressing
this button
indicates
that a sensor
wiII not be
connected
to the sensor
terminals
that correspond
with
the sensor
input
number
above
the first button
(see Field
Connections)
All sensor
inputs
that
are not used
must
be set to "NO".
>
- Next screen
Press
first
button
until
a 1 appears.
Then
press
button
under
"YES".
Press
first
button
until
a 2 appears.
Then
press
button
under
"NO".
Press
first
button
until
a 3 appears.
Then
press
button
under
"YES".
Repeat
for
sensor
inputs
4 thru
16
pressing
button
under
"NO"
for
each
input.
Press
button
under
">"
10)
Option
of delaying
a sensor
alarm.
The delay
prevents
nuisance
alarms
due to air entrapment
in the line
lines
and allows
sensors
to warm
when
first turning
power
on
to the
controller.
It is recommended
that
the
Delay
Alarm
be set
to 2.
ALARM
IMMEDIATE
OR
DELAY
IMMEDIATE
DELAY
IMMEDIATE
- The
controller
wiII
recognize
a sensor
alarm
immediately.
Same
as setting
the Delay
Alarm
to 1.
DELAY - When
a sensor
alarm
occurs
the controller
will mask
it and Increment
the Delay Alarm Counter
by one per
lube
cycle
Once
the
preset
number
for the
Delay
Alarm
Counter
has
been
reached
then
an alarm
wiII occur
The Delay Alarm
Counter
IS reset after all of the sensors
have
received
lube.
Press
button
under
"DELAY".
3