Download Print this page

Pentair LINCOLN SYSTEM SENTRY 84530 Owner's/Operator's Manual page 2

Sensor controller - internal scan

Advertisement

LIQUID
CRYSTAL
DISPLAY
The LCD has a bottom
to top viewing
angle
It is recommended
that
the
controller
be mounted
slightly
above
eye
level
for
optimum
viewing
The first line of the LCD is an instruction
Iine or a
message
The
second
line can have up to four commands,
each corresponding
to the button
beneath
it Pressing
the corresponding
button
wiII invoke
that
command
The following
example
shows
the
MAIN
MENU
MAIN
MENU
PLEASE
SELECT
SETUP
REVIEW
RUN
<
SETUP -
Pressing
the button
beneath
SETUP
wiII display
the
SETUP
MENU
REVIEW -
Pressing
the button
beneath
REVIEW
wiII display
the
REVIEW
SCREENS
RUN - Pressing
the
button
beneath
RUN
wiII
cause
controller
to function
as it was
programmed
in
SETUP
MENU
PROGRAMMING
MODE
the
the
To program
a new controller,
use the following
example
as a
guide
to match
the controller
to your
system
requirements
The internal
jumper
pin wiII be in the Program
position
for a
new controller
JUMPER IN
JUMPER IN
"PROGRAM"
POSITION
"RUN"
POSITION
If a controller
already
in use needs
to be reprogrammed,
the
internal
jumper
pin must
be moved
from
the Run position
to
the
Program
position
WARNING:
Turn
power
off
before
opening
enclosure
door
to move
jumper
pin.
If no buttons
are pressed
within
a 30 second
period, the display
wiII automatically
change
to ''SET JUMPER TO
RUN"
Pressing
the button
under
"<"
wiII display
the
MAIN
MENU
EXAMPLE:
The following
instructions
will
illustrate
how
to program
a
Sensor
Controller
-
Internal
Scan
with
these
sample
parameters
STEP
4
USING
SENSORS
?
5
LUBE
& SENSOR
CONTROLLER ?
6
SENSOR
CONTROLLER
ONLY
?
7
EXTERNAL
INPUT
FOR SCAN
?
8
SCAN
TIME
9
ACTIVATE
SENSOR
INPUTS
10
ALARM
IMMEDIATE
OR DELAY
?
11
NUMBER
OF FAULT
DELAYS
YES
NO
YES
NO
30 min
1&3
DELAY
2
1) Reminder
that
if the
Run
Mode
IS desired
the jumper
must
be set to Run
SET
JUMPER
TO
RUN
Press
button
under
"<".
2) Main
Menu
options
MAIN
MENU
PLEASE
SELECT
SETUP
REVIEW
RUN
SETUP -All
programming
options
are
available
in
the
Setup
Menu
REVIEW
- Can review
all system
parameters
that
have been
programmed
in the Setup
Menu
RUN - Controller
wiII function
as it was programmed
in the
Setup
Menu
Press
button
under
"SETUP".
3) Setup
Menu
options
CM -
SETUP
MENU
PLEASE
SELECT
CM
ML
SENSOR
<
Programming
options
for a Centro-Matic
Controller
(see
CM Manual)
ML - Programming
options
for a
Modular
Lube Controller
(see
ML Manual)
SENSOR
- Programming
options
for a Sensor
Controller
<
- WiII return
you to the previous
screen
Press
button
under
"SENSOR".
4) Choice
of using
sensors
USING
SENSORS
?
YES
NO
<
YES - Confirms
that
you are using
sensors
NO - Returns
you to the Main
Menu
<
- Returns
you to the
Setup
Menu
Press
button
under
"YES".
2