2. Centering of Needle Bar for Transforma
When the needle bar is correctly centered, the Needle Gauge No. 607801 or a straight needle size 90 or 100
(when looked at from front) must be exactly in the center of the stitch hole in the needle plate. If this
requirement is not met, proceed as follows:
Remove needle and presser foot.
Insert and fasten a Needle Gauge No. 607801 or a straight needle size 90 or 100.
Loosen the Stop Screw at the right of the head portion of the
upper casing.
Open the front cover.
Turn the flywheel slowly towards you until the Needle Bar is
in its lowest position.
Turn the Cradle Spring Screw clockwise or counterclockwise,
to adjust the Needle Bar so that the Gauge (or Needle), when
looked at from the front, is exactly in the center of the hole in
the needle plate.
Tighten the Stop Screw after adjustment.