Pioneer KEH-P7200RDS EW Service Manual page 16

Multi-cd control fm/mw/lw tuner deck amplifier
Hide thumbs Also See for KEH-P7200RDS EW:
Table of Contents

Advertisement

|
KEH-P7200RDSE,P71IOORDS,PEG200ORDS
,PEGIOORDS,P2S5ARDS,PISRDS
|
@ Error Numbers And New Test Mode
@ Indicating An Error Number
If the CD should fail to operate in CD multi player or if an error has taken place during the operation and resulted in
an error, the player will enter into the error mode. And the cause of such error is numerically indicated.
This is armed at assisting an analysis or repair.
(1) Basic Means of Display
"With ERROR indicated in "MODE" on IP-BUS Display date, an error code is transmitted by the use of MIN and SEC.
Identical date are transmitted with MIN and SEC.
-Examples of Display
ERROR-XX
(2) Error Codes
Code
|
ELECTRIC
Carriage doesn't move to or from the innermost position
—Home switch failed and/or carriage immobile
od
ELECTRIC
Focus failed
-~Defects, disc
upside-down, severe vibration
a
ELECTRIC
Spindle failed to lock or subcode unreadable
Subcode failure
—Spindle defective, defect, severe vibration
cz
ELECTRIC
Unrecorded CD-R
The disc is
upside-down, defects, vibration
ELECTRIC
AGC protect failed
—Defects, disc
upside-down, severe vibration
12
ELECTRIC
Failed to reach target address
—Carriage/tracking defective and/or defects
AO
SYSTEM
Power failure
Power overvoltage or short circuit detected
—Switching transistor defective and/or power abnormal
7
MECHANISM | An error upon ejection
MAG switch release time has time out
Elevation time out when eject
MECHANISM | An error while putting in
Tray in / out time has time out
and out the tra
Tray
is caught when
put in
MECHANISM
MECHANISM | An error with an empty
No disc is available
magazine inserted
* Setup means a series of operations after focusing up to sound output.
@ New Test Modelaging operation and setup analysis)
The single CD player plays in normal mode. After being set up, it will display FOK (focus), LOCK (spindle), subc ode,
sound skip, protection against a mechanical error or the like, occurrence of an error, cause and time of an expiry, if
any, (and disc number)
During the setup, the CD software operation status (internal RAM and C-point)is displayed.
(1) How to enter NEW TEST Mode
See the test mode flow chart Page 15.
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents