Follett R425A/W Installation, Operation And Service Manual page 18

Table of Contents

Advertisement

Normal operation – Stage 8
When the dwell time of 20 minutes has expired, the TIME DELAY LED goes off. If 5 seconds of ice has been
dispensed and the SLEEP CYCLE LED (Symphony Plus only) is off, the ice machine will go through the normal
start-up sequence when the bin level control signals the control board for ice.
Capacitor
OR
YELLOW
Water Sensors
Quiet Night/Sleep cycle (Symphony Plus only)
The board monitors ice dispensing through a line voltage input to P15. If the ice dispense has not be initiated for
more than 5 seconds during the 20 minute time delay, the SLEEP CYCLE LED comes on. The machine will stay
off for 12 hours unless 5 seconds of dispensing is seen. After 12 hours, the SLEEP CYCLE LED goes out and the
ice making will resume if the bin thermostat is closed. The sleep cycle dispense duration is adjustable using the
DIP switches on the control board.
18
MCD425A/W, R425A/W, MFD425A/W, P425A/W Ice Machines
T.O.L.
R
S
C
Compressor
2
RED
Start
Relay
5
Compressor
Electrical Box
WHITE
Start
Relay
Drain
Fill
4
Valve
Valve
3
2
BLACK
R
S
C
Gearmotor
A B C D
Drain Clog Sensor
Fan
1
WHITE
N
L1
L1
RED
P6
P21
P20
BROWN
P19
BLACK
P3
P22
BLUE
AUGER
Bin T-Stat
High
Pressure
Switch
POWER
N
P15
LOW BIN
BLACK
MAKING ICE
SLEEP CYCLE
HI PRS
TIME DELAY
LOW WATER
1 2 3 4 5 6 7 8
MAINTENANCE
RESET
SERVICE
HI AMPS
WATER LEVELS
HI PRESSURE
DRAIN CLOG
P11
BIN
P4
CLEANER FULL
Clean Switch

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mcd425a/wMfd425a/wP425a/wL77091K39864