Section 2.6.1

Mounting the Subscriber Station to a Wall or Tower

Mount the subscriber station to any wall or tower capable of supporting its weight. An outer wall on a roof or
other high location to avoid interference from other buildings or trees is preferred.
To mount the subscriber station to a wall or tower, do the following:
1.
Attach the subscriber station to the mounting bracket.
2
Figure 4: Mounting the Subscriber Station to a Wall or Tower
1. Subscriber Station    2. Mounting Kit    3. Wall Holder/Pole Mount    4. M8 × 25 mm Hex Screw    5. M8 Spring Washer    6. M8 Flat
Washer    7. M8 Nut    8. M5 Flat Washer    9. NS 1/4" × 1/2" HEX Chipboard Screw    10. Wall Anchor
2.
Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets,
washers and screws.
3.
Select a mounting location on the wall.
4.
Place the mounting bracket on the wall and mark four mounting holes.
5.
Drill four holes and insert a wall anchor into each hole.
6.
Secure the mounting bracket to the wall with four 1/4" × 1/2" HEX screws, four spring washers, and four flat
washers.
7.
Connect the arm bracket to the mounting bracket using a screw, spring washer, flat washer and nut. Make
sure the nut is hand tight
8.
Connect the subscriber station to the arm bracket using a screw, spring washer, flat washer and nut. Make
sure the nut is hand tight.
9.
Make sure the subscriber station is properly grounded according to local standards. For more information,
refer to
Section 2.8, "Grounding the Subscriber
Mounting the Subscriber Station to a Wall or Tower
3
8
4
5
6
Station".