Serial Terminals Connection - Panasonic TH-42PHW5 Operating Instructions Manual

High definition plasma display
Hide thumbs Also See for TH-42PHW5:
Table of Contents

Advertisement

Connections
SERIAL Terminals connection
The SERIAL terminal is used when the Plasma Display is controlled by a computer.
COMPUTER
o3ol
Ferrite core
_I,,,_
R.S-232C ,.
(large .size)
_
/
,
Less than
D-sub 9p
3" 15/16
(10cm)
Notes:
(1) Use the RS-232C cable to connect the computer to the Plasma Display.
(2) The computer shown is for example purposes only.
(3) Additional equipment and cables shown are not supplied with this set.
®®®®
/
J
Pin layout for RS-232C
J
Installing the ferrite core
(Large size)
Open
The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by
a computer which is connected to this terminal.
The computer will require software which allows the sending and receiving of control data which satisfies the conditions
given below. Use a computer application such as programming language software. Refer to the documentation
for the
computer application for details.
Communication
parameters
Signal level
Synchronization
method
Baud rate
Parity
Character length
Stop bit
Flow control
RS-232C compliant
Asynchronous
9600 bps
None
8 bits
1 bit
RS-232C Conversion cable
D-sub 9-pin female
Details
RXD
_)
TXD
_)
GND
(_* @
Non use
(_)
_
Shorted
(_0-@
NC
Command
Command
Parameter
Control details
PON
None
Power ON
POF
None
Power OFF
AVL
**
Volume 00 ~ 63
0
Audio MUTE OFF
AMT
1
Audio MUTE ON
IIS
None
Input select (toggle)
VID
VIDEO Mode
YP1
COMPONENT / RGBmode(processed a s
a Y/PB/PR or RGBsignals assetbythisunit)
RG1
PC mode
DAM
None
Screen mode select (toggle)
NORM
NORMAL (4:3)
ZOOM
ZOOM
FULL
FULL
JUST
JUST
SELF
Panasonic AUTO
Basic format for control data
The transmission of control data from the computer starts
with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order, if there
are no parameters, then the parameter signal does not
need to be sent.
/
LC°lon
L Parameter(s) L End
tart
• 3-character
(1 - 5 bytes)
(03h)
(O2h)
command (3bytes)
Notes:
(1) if multiple commands are transmitted, be sure to wait
for the response for the first command to come from
this unit before sending the next command.
(2) If an incorrect command is sent by mistake, this unit will
send an "ER401" command back to the computer.
With the power off, this display responds to PON command only.