Removal of Humidifier Unit
Step
5
Disconnect the 4 relay
connectors.
Disconnect the
6
connector for humidifier
fan motor.
Remove the 4 screws
7
of the humidifier unit
and lift it up to remove.
4
Procedure
Relay connectors
Mounting plate
Do not pull the harnesses
from the outdoor unit
strongly so as not to loose
the hook of the mounting
plate.
(See the illustration below
on this page for the
mounting plate.)
(R9886)
Be sure to wait 10 minutes
or more after turning off the
power supply before
disconnecting the
connectors.
Pull out the connector while
pushing up the hook on the
bottom side.
Humidifier
fan motor
(R9887)
}
<From the back side>
Humidifier unit
When lifting up the
Hook
humidifier unit, be careful
not to pull the relay
harnesses forcibly.
When reassembling the
humidifier unit, make sure
the mounting plate is
hooked (refer to page 21)
(R9888)
and do not forget to connect
the relay connectors.
Si12-992
Points
(R5796)