Removal Of Thermistors - Daikin Si12-992 Service Manual

Table of Contents

Advertisement

Si12-992

12.Removal of Thermistors

Procedure
Step
1. Removal of the assembly
of thermistor
1
Undo the clip and
remove the discharge
pipe thermistor.
Cut off the clamp to pull
2
out the outdoor heat
exchanger thermistor.
The outdoor air /
3
discharge pipe /
outdoor heat exchanger
thermistors are united
as one assembly.
The figure shows the
4
arrangement of the
assembly of thermistor
[S90].
2. Removal of the liquid /
gas pipe thermistors
1
Remove the liquid / gas
pipe thermistors.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Discharge pipe thermistor
Heat exchanger
thermistor
(R9984)
(R7631)
Outdoor air thermistor
(R9985)
(R9986)
Removal of Thermistors
Points
Be careful not to lose the clip
for the discharge pipe
thermistor.
(R7702)
Be careful not to lose the
clips for each thermistor.
37

Advertisement

Table of Contents
loading