9 Install the Unit

Installation of the CLR2160

1. Open the water supply valve in the main water source.
2. Plug in the power cord.
3. Open the door and press the POWER icon (see Figure
46, 1) on the display panel until OFF is displayed.
Note: If the unit is NOT turned OFF, water will
immediately start flowing into the unit when it is first
plugged into the electrical outlet.
4. Gently push the unit into position. Be careful not to
kink the drain or water supply line or entangle the
electrical cord.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit's top
surface should be approximately 1/8" below the
countertop.
6. Test the drain system by pouring one gallon of water
into the ice bin. The water should drain freely and there
should be no leakage.
www.U-LineService.com
CLR2160 — Clear Ice Maker

Installation Troubleshooting

Q:
Problem
Water is leaking under the unit.
A:
Solution
A water leak under the unit is most likely caused by a bad
connection in the water supply line. Make sure the water
line's brass fitting is screwed tight to its valve and
threaded correctly. Make sure the fill tube's connection to
the water line is also tight. Check drain line to make sure
it has not been disconnected from drain connection on
back of the unit or disconnected from the drain.
Q:
Problem
The door remains open unless it is pushed closed.
A:
Solution
The hinges should be self-closing when the door is open
approximately 8". If this is not the case, make sure the
closers (at the bottom of the hinge pin) are clean, greased
and installed correctly. Also, re-check leveling from front
to back of the unit and readjust if necessary. Make sure
that pivot plate is installed correctly.
Q:
Problem
The custom overlay door was designed to align with the
rest of the cabinet doors, but the unit has crept forward.
A:
Solution
First, make sure that the electrical cord and water supply
line are not obstructing the installation. If they are not,
there is mostly likely not enough room allowed for the
drain connection on the rear of the unit. You may need to
alter the wall behind the unit to accommodate the drain
connection.