Parameter
Unit's system voltage
and frequency
Unit configuration
Engine type
Engine data input types
g
p
yp
(N
(No magnetic pick-up)
i
i k
)
Battery voltage
Communications
Figure 8-8 Controller Parameters
TP-6335
9/04
Setting
Definition
Uu01
Single phase, 60 Hz, 120/240 VAC
Uc02
Mobile generator set
Ec03
10/13/15ERG
Ed00
All digital inputs
Ed01
Digital: Low coolant level and low oil pressure
Analog: Low coolant temperature
Ed02
Digital: Low coolant level and low coolant temperature
Analog: Low oil pressure
Ed03
Digital: Low coolant level
Analog: Low coolant temperature and low oil pressure
Ed08
Digital: Low coolant temperature and low oil pressure
Analog: Low coolant level
Ed09
Digital: Low oil pressure
Analog: Low coolant level and low coolant temperature
Ed10
Digital: Low coolant temperature
Analog: Low coolant level and low oil pressure
Ed11
All analog inputs
Bt12
Battery voltage 12 VDC
Cn00
No CAN communications
Cn01
SAE J1939 (Used for ADC remote digital gauge)
Cn02
Future CANbus