Kohler 13ERG Installation Manual page 24

Commercial mobile generator sets
Hide thumbs Also See for 13ERG:
Table of Contents

Advertisement

Note: Transfer switch. Use a triple-pole, double-throw
transfer switch rated for the calculated load of the
vehicle to transfer the load from one source to the
other. Install a ground-fault circuit interrupter in
the wiring system to protect all branch circuits.
Note: AC load circuit protection. Protect the AC load
circuit of the generator set against overloading or
short circuiting with a circuit breaker(s).
Note: For standby service connect output of the
generator to a suitably rated transfer switch in
accordance with the Canadian Electrical Code,
Part 1.
14 Electrical System
N
N
120-V
Outside
Power
N
N
240-V
Outside
Power
Figure 6-1 Transfer Switch Connections,
3-Wire AC Circuit
AC Vehicle Circuit
Ground Fault
Circuit Protection
L0
N
L1
Gen.
Set
L2
120 Volt
AC Vehicle Circuit
Ground Fault
Circuit Protection
L0
N
L1
Gen.
Set
L2
240 Volt
TP-6335
9/04

Advertisement

Table of Contents
loading

This manual is also suitable for:

10erg15erg

Table of Contents