Cleaning Condenser Coil - True TCM-78AC Installation Manual

Tcm models (convenience merchandiser)
Hide thumbs Also See for TCM-78AC:
Table of Contents

Advertisement

CLEANING THE CONDENSER COIL
TOOLS REQUIRED:
• Phillips Screwdriver
5
/
" Stiff Bristle Brush
64
• Adjustable Wrench
• Vacuum Cleaner
STEP 1
Unplug or disconnect power to the
cabinet.
STEP 2
Take off rear lower grill assembly
by removing two (2) bottom screws.
If necessary, loosen screws holding
the top pivot pins. Swing grill up
and remove frame hooks from pivot
pins at top of louver.
STEP 3
Remove bolts anchoring compressor
assembly to frame rails and care-
fully slide out. (tube connections
are flexible).
STEP 4
Clean off accumulated dirt from
condensing coil with a stiff bristle
brush.
STEP 5
Lift cardboard cover above fan at
plastic plugs and carefully clean
condenser coil and fan blades.
10
MAINTENANCE, CARE & CLEANING
After brushing condenser coil vacu-
um dirt from coil, and interior floor.
Replace cardboard cover. Carefully
slide compressor assembly back into
position and replace bolts.
Reinstall louver assembly onto unit,
tighten all screws.
Connect unit to power and check to
see if condensing unit is running.
............ www.truemfg.com ............
True Food Service Equipment, Inc.
STEP 6
STEP 7
STEP 8
STEP 9
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcm-84

Table of Contents