AM/CW FILTER INSTALLATION
Remove
the
top cover.
Locate
and
remove
PB-
1716 (FILTER
UNIT). Referring to Fig. 1, locate
jumpers A and B on the printed board. If the AM
filter is to be installed,
the jumper
marked
A
must be installed, and for CW
filter installation
the jumper marked B must be removed.
Referring
to Figs.
1 and
2, install the desired
filter in the appropriate holes. Make the fastening
nuts snug (CW filter only), and solder the pins of
the filter to the printed board.
Re-install PB-1716
in the chassis socket, and re-
place the cover of the transceiver.
Cw
FILTER
Lock Washer
'SpringWasher
Nut
Figure 2
SERVICING
Figure
1
8S300601ZG