Servicing The Fuses; Drive System Maintenance; Checking The Tire Pressure - Toro 74732 Operator's Manual

Table of Contents

Advertisement

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse type:
Main—F1 (30 A, blade-type)
Charge Circuit—F2 (25 A, blade-type)
1.
Remove the screws securing the control panel
to the machine.
Note:
Retain all fasteners.
2.
Lift the control pane up to access the main wire
harness and fuse block
3.
To replace a fuse, pull out on the fuse to remove
it
(Figure
42).
Figure 42
1. Main (30 A)
4.
Return the control panel to its original position.
Note:
Use the screws removed previously to
secure the panel to the machine.
(Figure
42).
g014921
2. Charge circuit (25 A)
Drive System
Maintenance

Checking the Tire Pressure

Service Interval: Every 25 hours—Check tire
pressure.
Maintain the air pressure in the front and rear tires as
specified. Uneven tire pressure can cause uneven
cut. Check the pressure at the valve stem
Check the tires when they are cold to get the most
accurate pressure reading.
Refer to the maximum pressure suggested by the tire
manufacturer on the sidewall of the caster wheel tires.
Inflate the rear drive wheel tires to 90 kPa (13 psi).
1. Valve stem
35
(Figure
Figure 43
43).
g000554

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timecutter ss 500074721Timecutter ss 4225