AC Load Lead Connections

Each set has four color-coded load leads. The black
leads (L1 and L2) are hot, the white lead (L0) is neutral
and the green lead is the hazard ground. Route the load
leads directly from the junction box to the vehicle AC
circuit or transfer-switch connection. All installations
require that the load leads be routed through flexible
conduit from the generator end bracket to the junction
box location.
The load lead junction box must be
accessible for servicing and inspection.
Keep load lead circuit away from the generator,
specifically fuel and exhaust system components.
All field-supplied wiring must be capable of withstanding
temperatures of 167_ F (75_ C).
AC load lead L0 (white or gray) is always the neutral lead
on Kohler generator sets. Make sure the neutral of the
N
N
120-V
Outside
Power
120 Volt
TP-5605 4/97
NOTE
NOTE
AC Vehicle Circuit
Ground Fault
Circuit Protection
L0
N
L1
Gen.
Set
L2
Figure 6-17. Transfer Switch Connections, 3-Wire AC Circuit
AC circuit in the vehicle is connected to the lead L0
(white or gray). If equipment ground-type plugs and
receptacles (3-pronged) are used in the vehicle, the
green wire must be connected to the U-shaped pin. On
vehicles which also have provisions for using an outside
AC power source, the neutral as well as the hot (or
black) leads must be completely isolated from the
generator set when power is switched to the outside
source. See Figure 6-17.
Use a triple-pole, double-throw transfer switch rated for
the calculated load of the RV to transfer the load from
one source to the other. Install a ground-fault circuit
interrupter in the wiring system to protect all branch
circuits.
The AC load circuit of the generator set must be
protected by a circuit breaker(s) against overload or
short circuit.
N
N
240-V
Outside
Power
120/240 Volt
NOTE
NOTE
AC Vehicle Circuit
Ground Fault
Circuit Protection
L0
N
L1
Gen.
Set
L2
Installation 6-19

Advertisement