Your vehicle is equipped with a dependable Kohler
alternating-current RV/Mobile Generator Set. Service
requirements of the generator set are minimal, but it is
important that the required services be performed at the
prescribed intervals. Please take a few moments to
read through this manual; then carefully follow all
service recommendations to keep your set in top
condition. In the space provided, record the MODEL,
SPECIFICATION,
SERIAL and
numbers as found on the nameplate attached to the belt
Dimensions L x W x H in. (mm):
Remote Radiator (Single Phase)
Remote Radiator (Single Phase) Airbag Mounted
In-line Radiator (Single Phase)
In-line Radiator (Three Phase)
Weight— dry, lbs. (kg):
Remote Radiator (Single Phase)
Remote Radiator (Single Phase) Airbag Mounted
In-line Radiator (Single Phase)
In-line Radiator (Three Phase)
Air Requirements CFM (M
Combustion.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cooling
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuel Inlet Size in. (mm)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuel Return Size in. (mm)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuel Consumption gph (Lph):
Load
15 kW
20 kW
DERATION: All units are rated 1.0 power factor. The kilowatts of the generator set will decrease 3.5% for each 1,000 feet (305 meters) above
500 feet (152 meters) above sea level and 1% for each 10_ F (5.5_ C) above 85_ F (30_ C).
TP-5605 4/97
Section 1. Specifications
Introduction
ENGINE SPEC.
General Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
/min):
25%
0.6 (2.3)
0.9 (3.4)
guard of the engine for remote-radiator models and on
the radiator bracket for in-line radiator models (see
Section 8 " Service Ordering Instructions" ).
information will enable your Kohler Generator Service
Dealer/Distributor to supply the correct part or data for
your particular version. Keep this manual in your vehicle
for future reference. The illustrations in this manual are
representative of most units. Your generator set may
differ slightly from those shown.
15 kW (60Hz)
39.57 x 20.89 x 25.61
(1005 x 531 x 650)
. . . . . . . . . . . .
39.57 x 22.00 x 25.61
(1005 x 559 x 650)
45.02 x 20.99 x 28.00
(1144 x 533 x 711)
46.62 x 20.99 x 28.00
(1184 x 533 x 711)
684 (310)
. . . . . . . . . . . . . . . . . . . .
N/A
719 (326)
719 (326)
70 (2)
1930 (55)
1/4-18 N.P.S.F
1/4-18 N.P.S.F
50%
0.8 (3.0)
1.2 (4.5)
20 kW (60Hz)
. . . . . . . .
39.57 x 20.89 x 27.25
(1005 x 531 x 692)
. . . . . . . .
39.57 x 22.00 x 28.51
(1005 x 559 x 724)
. . . . . . . .
45.02 x 20.99 x 28.00
(1144 x 533 x 711)
. . . . . . . .
46.62 x 20.99 x 28.00
(1184 x 533 x 711)
. . . . . . . . . . . . . . . . . .
695 (315)
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
730 (331)
. . . . . . . . . . . . . . . . . .
730 (331)
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
1930 (55)
. . . . . . . . . . . . . .
1/4-18 N.P.S.F
. . . . . . . . . . . . . .
1/4-18 N.P.S.F
75%
1.1 (4.2)
1.5 (5.7)
This
N/A
70 (2)
100%
1.4 (5.3)
1.9 (7.2)
Specifications 1-1