Figure D-2. Bsc Control Unit Address Switch Setting - IBM 3270 Manual

Hide thumbs Also See for 3270:
Table of Contents

Advertisement

Control Unit Address
EBCDIC EBCDIC ASCII
Poll
Selection Poll
Address
Address
Address
{Hex)
{Hex)
(Hex)
40
60
20
C1
61
41
C2
E2
42
C3
E3
43
C4
E4
44
C5
E5
45
C6
E6
46
C7
E7
47
C8
E8
48
C9
E9
49
4A
6A
58
48
68
2E
14C
6C
3C
40
60
28
l4E
6E
28
4F
6F
21
1
"8" Switches
1
=Switch ON
0 =Switch OFF
ASCII
BSC
Selection
Address
Address
CU No.
Switches
{Hex)
{Decimal)
12345
20
0
00000
2F
1
00001
53
2
00010
54
3
00011
55
4
00100
56
5
00101
57
6
00110
58
7
00111
59
8
01000
5A
9
01001
7C
10
01010
2C
11
01011
25
12
01100
5F
13
01101
3E
14
01110
3F
15
01111
Control Unit Address
EBCDIC EBCDIC ASCII
ASCII
BSC
Poll
Selection Poll
Selection
Address
Address
Address
Address
Address
CU No.
Switches
{Hex)
{Hex)
{Hex)
(Hex)
(Decimal)
12345
50
FO
26
30
16
10000
01
F1
4A
31
17
10001
02
F2
48
32
18
10010
03
F3
4C
33
19
10011
04
F4
40
34
20
10100
05
F5
4E
35
21
10101
06
F6
4F
36
22
10110
07
F7
50
37
23
10111
08
F8
51
38
24
11000
09
F9
52
39
25
11001
5A
7A
50
3A
26
11010
58
78
24
23
27
11011
5C
7C
2A
40
28
11100
50
70
29
27
29
11101
5E
7E
38
30
30
11110
5F
7F
5E
22
31
11111
Figure D-2. BSC Control Unit Address Switch Setting (Switches Bl-85)
In the FDX (ON) position and
• When SDLC protocol is being used, this switch causes continuous carrier operation by
keeping Request to Send on continuously.
• When BSC protocol is being used, this switch causes continuous carrier operation only
when the 3276 is selected (to avoid turnaround time). When EOT is detected (sent
from either end of the line), carrier operation is turned off.
The switch should be set to FDX (ON) when:
• BSC protocol is being used in 4-wire, point-to-point operation.
• SDLC protocol is being used in 4-wire, point-to-point operation.
In addition,
• If
the 32 76 is configured for leased-line operation (for example, by Special Feature
3701, External Modem Interface, and Specify Feature 9491, for operation on private
nonswitched communication facilities), a jumper wire is installed at the plant of
manufacture. The jumper permits switch B6 to be used on a leased line, selecting
either continuous carrier or noncontinuous carrier as described above. However, if the
leased line goes down, and the terminal is to operate in switched network backup
(SNBU) mode, setting the SNBU switch
in
the SNBU (UP) position forces
noncontinuous carrier operation (that is, switch B6 is not operative).
• If
the 3276 is configured for full-time switched network operation (that is by Special
Feature 3701, External Modem Interface, and Specify Feature 9490, for SDLC
operation on public switched network), the jumper wire is omitted. Switch B6 is
disabled, and half-duplex (noncontinuous carrier operation) is forced.
The switch should be set as summarized in Figure D-3.
The example (Figure D-6) shows how the 3276 Switch Settings Form should be filled in
to set the switch for FDX. Fill in the switch B6 portion of item 2 on the form.
41