Figure D-1. Sdlc Address Switch Setting - IBM 3270 Manual

Hide thumbs Also See for 3270:
Table of Contents

Advertisement

Control
SDLC Address
Unit
Hex
Switches 1
Address
12345678
01
00000001
02
00000010
03
00000011
04
00000100
05
00000101
06
00000110
07
00000111
08
00001000
09
00001001
OA
00001010
OB
00001011
QC
00001100
OD
00001101
OE
00001110
OF
00001111
10
00010000
11
00010001
12
00010010
13
00010011
14
00010100
15
00010101
16
00010110
17
00010111
18
00011000
19
00011001
1 "A" Switches
1 =Switch ON
0 =Switch
OFF
Control
SDLC Address
Control
Unit
Hex
Switches 1
Unit
Hex
Address
12345678
Address
1A
00011010
60
1B
00011011
70
1C
00011100
80
10
00011101
90
1E
00011110
AO
1F
00011111
BO
20
00100000
co
21
00100001
DO
22
00100010
EO
23
00100011
FO
24
00100100
F1
25
00100101
F2
26
00100110
F3
27
00100111
F4
28
00101000
F5
29
00101001
F6
2A
00101010
F7
2B
00101011
F8
2C
00101100
F9
2D
00101101
FA
2E
00101110
FB
2F
00101111
FC
30
00110000
l
FD
40
01000000
~
2
FE
50
01010000
2
Use addresses 01 - OF as necessary.
Ex: Address AD= AO 10100000
+OD 00001101
AD 10101101
Figure D·l. SDLC Address Switch Setting (Switches Al-AS)
SDLC Address
Switches 1
12345678
01100000\
01110000
10000000
10010000
10100000
>2
10110000
11000000
11010000
11100000 /
11110000
11110001
11110010
11110011
11110100
11110101
11110110
11110111
11111000
11111001
11111010
11111011
11111100
11111101
11111110
To determine the "B" switch settings, first obtain the control unit number (decimal 0-31)
or the control unit address (in EBCDIC hexadecimal) from the system programmer. Using
either address designation, look up the "B" switch settings in Figure D-2. For example, a
control unit address of hexadecimal SA (control unit number of decimal 26) requires that
switches Bl, B2, and B4 be set to ON and switches B3 and BS to OFF.
Item 2 in the example of the 3276 Switch Settings Form (Figure D-6, at the end of this
appendix) shows how the form should be filled in for control unit address SA (control
unit 26). Fill in Bl-BS of item 2 on the form.
Switch B6: Full-Duplex (FDX)/Half-Duplex (HDX) Switch (Except Loop Adapter Feature Machines)
40
In the HDX (OFF) position, this switch causes noncontinuous carrier operation. That is,
the Request to Send lead to the modem is on only when the 3276 wants to transmit. The
switch should be set to HDX when:
• BSC or SDLC protocol is being used in 2-wire operation.
• SDLC protocol is being used in 4-wire, leased-line, multipoint operation.
When the host modem has the NEWSYNC feature and the required host program support,
the HDX(OFF) position must be selected.