DEVIreg™ Touch
Note: A oor sensor enables a more accurate
temperature control and is recommended in
all oor heating applications and mandatory
under wooden oors to reduce the risk of
over-heating the oor.
• Place the oor sensor in a conduit in an appropriate
place where it is not exposed to sunlight or draft from
door openings.
• Equally distant and >2cm from two heating cables.
• The conduit should be ush with the oor surface -
countersink the conduit if necessary.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50mm.